NSN 5950-01-011-5348 · NIIN 010115348 · FSC 5950
NO DASHES 5950010115348
In Stock
TRANSFORMER,POWER
Coils and Transformers
Technical characteristics
23 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES MINIMUM 1.210 AND INCHES MAXIMUM 1.270 |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES MINIMUM 0.780 AND INCHES MAXIMUM 0.840 |
| ABMK | OVERALL WIDTH | INCHES MAXIMUM 1.710 |
| ABTB | MOUNTING HOLE DIAMETER | SINGLE GROUP INCHES MINIMUM 0.178 AND INCHES MAXIMUM 0.198 |
| ACZB | FREQUENCY RATING | SINGLE COMPONENT KILOHERTZ MINIMUM 4.0 AND KILOHERTZ MAXIMUM 5.0 |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE |
| ADAQ | BODY LENGTH | INCHES MINIMUM 1.590 AND INCHES MAXIMUM 1.710 |
| ADAU | BODY HEIGHT | INCHES MINIMUM 1.220 AND INCHES MAXIMUM 1.280 |
| AEHZ | MAXIMUM OPERATING TEMP | CELSIUS 130.0 |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AKPV | MOUNTING FACILITY QUANTITY | 2 |
| AXGY | MOUNTING METHOD | SINGLE GROUP UNTHREADED HOLE(S) |
| BPLC | WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND SECONDARY 3 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT FIRST SECONDARY MILLIAMPERES DC NOMINAL 100.0 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT THIRD SECONDARY AMPERES DC NOMINAL 2.5 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT SECOND SECONDARY AMPERES DC NOMINAL 1.0 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 53.03 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT THIRD SECONDARY AC VOLTS NOMINAL 7.07 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 5.66 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 7.07 |
| TEST | TEST DATA DOCUMENT | DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) 06401-7904518 |
| TTQY | TERMINAL TYPE AND QUANTITY | TURRET 12 |
Cross-references
3 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| 3-19620 | 00144 |
| 7904518-00 | 06401 |
| 8960 | 05254 |