NSN 5950-01-011-9263 · NIIN 010119263 · FSC 5950
NO DASHES 5950010119263
In Stock
REACTOR
Coils and Transformers
Technical characteristics
17 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 1.250 |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 1.000 |
| ABTD | MOUNTING SLOT WIDTH | SINGLE GROUP INCHES NOMINAL 0.125 |
| ACYF | INDUCTANCE TYPE | FIXED |
| ACYV | INDUCTANCE RATING | SINGLE COMPONENT SINGLE WINDING MILLIHENRIES NOMINAL 1.50 |
| ADAQ | BODY LENGTH | INCHES MAXIMUM 1.500 |
| ADAT | BODY WIDTH | INCHES MAXIMUM 1.250 |
| ADAU | BODY HEIGHT | INCHES MAXIMUM 1.530 |
| AKDX | WINDING QUANTITY | 1 |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AKPV | MOUNTING FACILITY QUANTITY | 4 |
| AXGY | MOUNTING METHOD | SINGLE GROUP FLANGE AND SLOT |
| BKPL | RATING METHOD | SINGLE COMPONENT SINGLE WINDING ELECTRICAL |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT SINGLE WINDING AMPERES DC MAXIMUM 9.0 |
| CRGS | DC RESISTANCE RATING IN OHMS | 0.120 |
| TTQY | TERMINAL TYPE AND QUANTITY | WIRE LEAD 2 |
Cross-references
1 manufacturer part number on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| 18-77-3 | 21562 |