NSN 5950-01-027-4029 · NIIN 010274029 · FSC 5950
NO DASHES 5950010274029
In Stock
TRANSFORMER,POWER
Coils and Transformers
Technical characteristics
16 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ACZB | FREQUENCY RATING | SINGLE COMPONENT HERTZ NOMINAL 50.0 OR HERTZ NOMINAL 60.0 |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE |
| ACZX | WINDING SHIELDING METHOD | SINGLE COMPONENT INTERNAL SHIELD BROUGHT OUT TO TERMINAL |
| ADAQ | BODY LENGTH | INCHES NOMINAL 2.281 |
| ADAT | BODY WIDTH | INCHES MAXIMUM 2.125 |
| ADAU | BODY HEIGHT | INCHES NOMINAL 1.906 |
| AEHZ | MAXIMUM OPERATING TEMP | CELSIUS 125.0 |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AXGY | MOUNTING METHOD | SINGLE GROUP TERMINAL |
| BPLC | WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND SECONDARY 1 |
| CBBL | FEATURES PROVIDED | COLOR CODED LEAD |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT SINGLE SECONDARY MILLIAMPERES AC MINIMUM 140.0 AND MILLIAMPERES AC MAXIMUM 300.0 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE SECONDARY AC VOLTS NOMINAL 15.30 AND AC VOLTS NOMINAL 30.70 AND AC VOLTS NOMINAL 46.00 AND AC VOLTS NOMINAL 61.30 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 105.00 AND AC VOLTS NOMINAL 115.00 |
| TTQY | TERMINAL TYPE AND QUANTITY | WIRE LEAD 9 |
Cross-references
3 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.
Supersedes
This item replaces cancelled NIIN 011859754. An older drawing citing one of those numbers resolves here.