NSN 5950-01-031-7680 · NIIN 010317680 · FSC 5950
NO DASHES 5950010317680
In Stock
TRANSFORMER,POWER
Coils and Transformers
Technical characteristics
21 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABHP | OVERALL LENGTH | INCHES MAXIMUM 3.625 |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES MAXIMUM 3.250 |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES MAXIMUM 1.750 |
| ABKW | OVERALL HEIGHT | INCHES MAXIMUM 4.188 |
| ABTB | MOUNTING HOLE DIAMETER | SINGLE GROUP INCHES NOMINAL 0.161 |
| ACZB | FREQUENCY RATING | SINGLE COMPONENT HERTZ MINIMUM 400.0 AND KILOHERTZ MAXIMUM 1.2 |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT THREE PHASE TO THREE PHASE |
| ACZD | TRANSFORMER WINDING CONNECTION TYPE | OPEN DELTA-OPEN DELTA |
| ACZF | MAXIMUM TRANSFORMER POWER RATING | SINGLE COMPONENT WATTS 100.0 |
| ADAT | BODY WIDTH | INCHES MAXIMUM 2.562 |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AKPV | MOUNTING FACILITY QUANTITY | 4 |
| AXGY | MOUNTING METHOD | SINGLE GROUP BRACKET(S) AND UNTHREADED HOLE(S) |
| BPLC | WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND SECONDARY 3 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT SINGLE PRIMARY MILLIAMPERES AC MAXIMUM 70.0 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 13.50 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 21.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 115.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT THIRD SECONDARY AC VOLTS NOMINAL 21.00 |
| TTQY | TERMINAL TYPE AND QUANTITY | WIRE HOOK 12 |