NSN 5950-01-042-1947 · NIIN 010421947 · FSC 5950
NO DASHES 5950010421947
In Stock
TRANSFORMER,POWER
Coils and Transformers
Technical characteristics
20 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABHP | OVERALL LENGTH | INCHES MINIMUM 2.626 AND INCHES MAXIMUM 2.718 |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES MINIMUM 1.984 AND INCHES MAXIMUM 2.016 |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES MINIMUM 1.484 AND INCHES MAXIMUM 1.516 |
| ABKW | OVERALL HEIGHT | INCHES MINIMUM 3.751 AND INCHES MAXIMUM 3.999 |
| ABMK | OVERALL WIDTH | INCHES MINIMUM 2.094 AND INCHES MAXIMUM 2.156 |
| ACZB | FREQUENCY RATING | SINGLE COMPONENT HERTZ NOMINAL 60.0 |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE |
| ACZF | MAXIMUM TRANSFORMER POWER RATING | SINGLE COMPONENT VOLT-AMPERE 30.0 |
| ACZX | WINDING SHIELDING METHOD | SINGLE COMPONENT INTERNAL SHIELD GROUNDED TO CORE |
| AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
| AKPV | MOUNTING FACILITY QUANTITY | 4 |
| AXGY | MOUNTING METHOD | SINGLE GROUP THREADED HOLE(S) |
| BPLC | WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND SECONDARY 1 |
| CQJX | NOMINAL THREAD SIZE | SINGLE GROUP INCHES 0.164 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT SINGLE SECONDARY AMPERES AC NOMINAL 3.0 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 115.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE SECONDARY AC VOLTS NOMINAL 10.00 |
| THSD | THREAD SERIES DESIGNATOR | SINGLE GROUP UNIFIED NATIONAL COARSE (UNC) |
| TTQY | TERMINAL TYPE AND QUANTITY | WIRE HOOK 5 |