| MRC | Requirement | Value |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABHP | OVERALL LENGTH | INCHES NOMINAL 5.250 |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 4.000 |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 4.000 |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 4.750 |
| ABMK | OVERALL WIDTH | INCHES NOMINAL 4.250 |
| ACZB | FREQUENCY RATING | SINGLE COMPONENT HERTZ MINIMUM 45.0 AND HERTZ MAXIMUM 65.0 |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AKPV | MOUNTING FACILITY QUANTITY | 4 |
| AXGY | MOUNTING METHOD | SINGLE GROUP BRACKET(S) |
| BPLC | WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 2 AND SECONDARY 2 |
| CQJX | NOMINAL THREAD SIZE | SINGLE GROUP INCHES 0.250 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT FIRST SECONDARY AMPERES AC MAXIMUM 22.0 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT SECOND SECONDARY AMPERES AC MAXIMUM 0.1 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 36.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT ALL PRIMARY AC VOLTS NOMINAL 120.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 7.00 |
| THSD | THREAD SERIES DESIGNATOR | SINGLE GROUP UNIFIED NATIONAL COARSE (UNC) |
| TTQY | TERMINAL TYPE AND QUANTITY | THREADED STUD 3 AND CONNECTOR, PLUG 1 |