NSN 5950-01-050-0586 · NIIN 010500586 · FSC 5950
NO DASHES 5950010500586
In Stock
TRANSFORMER,POWER
Coils and Transformers
Technical characteristics
18 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABHP | OVERALL LENGTH | INCHES NOMINAL 3.250 |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 1.938 |
| ABMK | OVERALL WIDTH | INCHES NOMINAL 1.688 |
| ABTB | MOUNTING HOLE DIAMETER | SINGLE GROUP INCHES NOMINAL 0.187 |
| ACZB | FREQUENCY RATING | SINGLE COMPONENT HERTZ MINIMUM 50.0 AND HERTZ MAXIMUM 60.0 |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE |
| ACZF | MAXIMUM TRANSFORMER POWER RATING | SINGLE COMPONENT VOLT-AMPERE 30.0 |
| AEHZ | MAXIMUM OPERATING TEMP | CELSIUS 130.0 |
| AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 2.812 |
| AKNA | INCLOSURE TYPE | PARTIALLY INCLOSED |
| AKPV | MOUNTING FACILITY QUANTITY | 2 |
| AXGY | MOUNTING METHOD | SINGLE GROUP FLANGE AND UNTHREADED HOLE(S) |
| BPLC | WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND SECONDARY 1 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT SINGLE SECONDARY AMPERES AC NOMINAL 3.0 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE SECONDARY AC VOLTS NOMINAL 10.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 115.00 |
| TTQY | TERMINAL TYPE AND QUANTITY | QUICK DISCONNECT, FEMALE 5 OR TAB, SOLDER LUG 5 |