NSN 5950-01-064-9276 · NIIN 010649276 · FSC 5950
NO DASHES 5950010649276
In Stock
TRANSFORMER,POWER
Coils and Transformers
Technical characteristics
25 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES MINIMUM 3.295 AND INCHES MAXIMUM 3.325 |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES MINIMUM 2.235 AND INCHES MAXIMUM 2.265 |
| ABTD | MOUNTING SLOT WIDTH | SINGLE GROUP INCHES NOMINAL 0.188 |
| ACZB | FREQUENCY RATING | SINGLE COMPONENT HERTZ NOMINAL 400.0 |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE |
| ACZX | WINDING SHIELDING METHOD | SINGLE COMPONENT INTERNAL SHIELD GROUNDED TO INCLOSURE |
| ADAQ | BODY LENGTH | INCHES MINIMUM 3.735 AND INCHES MAXIMUM 3.765 |
| ADAT | BODY WIDTH | INCHES MINIMUM 2.795 AND INCHES MAXIMUM 2.825 |
| ADAU | BODY HEIGHT | INCHES MINIMUM 3.365 AND INCHES MAXIMUM 3.395 |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AKPV | MOUNTING FACILITY QUANTITY | 4 |
| AXGY | MOUNTING METHOD | SINGLE GROUP SLOT |
| BPLC | WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND SECONDARY 5 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT FOURTH SECONDARY MILLIAMPERES AC MAXIMUM 100.0 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT THIRD SECONDARY AMPERES AC MAXIMUM 2.0 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT FIRST SECONDARY AMPERES AC MAXIMUM 7.0 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT SECOND SECONDARY AMPERES AC MAXIMUM 1.0 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT FIRST SECONDARY AC VOLTS MINIMUM 42.75 AND AC VOLTS MAXIMUM 47.25 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 115.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT FOURTH SECONDARY AC VOLTS MINIMUM 73.15 AND AC VOLTS MAXIMUM 80.85 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SECOND SECONDARY AC VOLTS MINIMUM 42.75 AND AC VOLTS MAXIMUM 47.25 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT THIRD SECONDARY AC VOLTS MINIMUM 16.63 AND AC VOLTS MAXIMUM 18.38 |
| FEAT | SPECIAL FEATURES | 1PRIMARY,5 SECONDARY WINDINGS |
| TTQY | TERMINAL TYPE AND QUANTITY | TAB, SOLDER LUG 12 |
Cross-references
5 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| 240-423-17A | 59559 |
| 44202 | 73386 |
| 240-423-17A | 03040 |
| 240-423.17A | 05853 |
| 240-423.17A | 11850 |