Technical characteristics

32 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
AARGRELIABILITY INDICATORNOT ESTABLISHED
ABKQCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 2.812
ABKRCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 1.750
ABTBMOUNTING HOLE DIAMETERSINGLE GROUP INCHES NOMINAL 0.187
ACZBFREQUENCY RATINGSINGLE COMPONENT HERTZ NOMINAL 400.0
ACZCINPUT-OUTPUT PHASE RELATIONSHIPSINGLE COMPONENT THREE PHASE TO SINGLE PHASE AND THREE PHASE TO THREE PHASE
ACZDTRANSFORMER WINDING CONNECTION TYPEDELTA-DELTA
ACZFMAXIMUM TRANSFORMER POWER RATINGSINGLE COMPONENT VOLT-AMPERE 291.9
ACZXWINDING SHIELDING METHODSINGLE COMPONENT INTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL
ADAQBODY LENGTHINCHES MAXIMUM 4.750
ADATBODY WIDTHINCHES MAXIMUM 2.500
ADAUBODY HEIGHTINCHES MAXIMUM 4.000
AEHZMAXIMUM OPERATING TEMPCELSIUS 155.0
AKNAINCLOSURE TYPEFULLY INCLOSED
AKPVMOUNTING FACILITY QUANTITY4
AXGYMOUNTING METHODSINGLE GROUP UNTHREADED HOLE(S)
BPLCWINDING FUNCTION AND QUANTITYSINGLE COMPONENT PRIMARY 1 AND SECONDARY 12
CRBZWINDING OPERATING CURRENTSINGLE COMPONENT FOURTH SECONDARY MILLIAMPERES AC NOMINAL 173.0
CRBZWINDING OPERATING CURRENTSINGLE COMPONENT THIRD SECONDARY AMPERES AC NOMINAL 1.84
CRBZWINDING OPERATING CURRENTSINGLE COMPONENT SECOND SECONDARY MILLIAMPERES AC NOMINAL 81.0
CRBZWINDING OPERATING CURRENTSINGLE COMPONENT FIRST SECONDARY MILLIAMPERES AC NOMINAL 204.0
CRMJWINDING POWER RATINGSINGLE COMPONENT FOURTH SECONDARY VOLTS-AMPERES 3.0
CRMJWINDING POWER RATINGSINGLE COMPONENT THIRD SECONDARY VOLTS-AMPERES 31.8
CRMJWINDING POWER RATINGSINGLE COMPONENT SECOND SECONDARY VOLTS-AMPERES 2.8
CRMJWINDING POWER RATINGSINGLE COMPONENT FIRST SECONDARY VOLTS-AMPERES 7.0
CWJSWINDING OPERATING VOLTAGESINGLE COMPONENT THIRD SECONDARY AC VOLTS NOMINAL 10.00
CWJSWINDING OPERATING VOLTAGESINGLE COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 19.80
CWJSWINDING OPERATING VOLTAGESINGLE COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 19.80
CWJSWINDING OPERATING VOLTAGESINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 196.00
CWJSWINDING OPERATING VOLTAGESINGLE COMPONENT FOURTH SECONDARY AC VOLTS NOMINAL 10.00
FEATSPECIAL FEATURESONE PRIMARY WINDING; TWELVE SECONDARY WINDINGS
TTQYTERMINAL TYPE AND QUANTITYTAB, SOLDER LUG 39

Cross-references

5 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.

Manufacturer cross-reference part numbers and CAGE codes
Manufacturer part numberCAGE
4265422558
WE-319226543
C1358372149
SM-A-87866480063
WE-319215634