NSN 5950-01-092-0889 · NIIN 010920889 · FSC 5950
NO DASHES 5950010920889
In Stock
TRANSFORMER,POWER
Coils and Transformers
Technical characteristics
29 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SECOND MOUNTING FACILITY SINGLE CENTER GROUP INCHES MINIMUM 4.458 AND INCHES MAXIMUM 4.478 |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SECOND MOUNTING FACILITY SINGLE CENTER GROUP INCHES MINIMUM 4.240 AND INCHES MAXIMUM 4.260 |
| ACZB | FREQUENCY RATING | SINGLE COMPONENT HERTZ NOMINAL 60.0 |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT THREE PHASE TO SIX PHASE AND THREE PHASE TO THREE PHASE |
| ACZD | TRANSFORMER WINDING CONNECTION TYPE | DELTA-DELTA AND DELTA-WYE |
| ADAQ | BODY LENGTH | INCHES MAXIMUM 6.300 |
| ADAT | BODY WIDTH | INCHES MINIMUM 5.110 AND INCHES MAXIMUM 5.150 |
| ADAU | BODY HEIGHT | INCHES MAXIMUM 4.750 |
| AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | THIRD MOUNTING FACILITY SINGLE CENTER GROUP INCHES MINIMUM 5.490 AND INCHES MAXIMUM 5.510 |
| AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | FIRST MOUNTING FACILITY SINGLE CENTER GROUP INCHES MINIMUM 5.740 AND INCHES MAXIMUM 5.760 |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AKPV | MOUNTING FACILITY QUANTITY | 4 |
| AKPV | MOUNTING FACILITY QUANTITY | 2 |
| AXGY | MOUNTING METHOD | ALL GROUPINGS THREADED HOLE(S) |
| BPLC | WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND SECONDARY 11 |
| CQJX | NOMINAL THREAD SIZE | FIRST GROUP INCHES 0.112 |
| CQJX | NOMINAL THREAD SIZE | THIRD GROUP INCHES 0.164 |
| CQJX | NOMINAL THREAD SIZE | SECOND GROUP INCHES 0.164 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT SINGLE PRIMARY AMPERES AC MAXIMUM 1.2 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 200.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT FOURTH SECONDARY AC VOLTS NOMINAL 31.05 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT THIRD SECONDARY AC VOLTS NOMINAL 15.13 AND AC VOLTS NOMINAL 30.25 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 15.69 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 72.83 |
| FEAT | SPECIAL FEATURES | 1 PRIMARY WINDING; 11 SECONDARY WINDINGS |
| PRPY | PROPRIETARY CHARACTERISTICS | PACS |
| THSD | THREAD SERIES DESIGNATOR | ALL GROUPINGS UNIFIED NATIONAL COARSE (UNC) |
| TTQY | TERMINAL TYPE AND QUANTITY | TAB, SOLDER LUG 50 |