NSN 5950-01-093-8574 · NIIN 010938574 · FSC 5950
NO DASHES 5950010938574
In Stock
REACTOR
Coils and Transformers
Technical characteristics
20 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ACYF | INDUCTANCE TYPE | FIXED |
| ACYV | INDUCTANCE RATING | SINGLE COMPONENT SINGLE WINDING MILLIHENRIES NOMINAL 20.00 |
| ACZB | FREQUENCY RATING | SINGLE COMPONENT HERTZ NOMINAL 400.0 |
| ADAQ | BODY LENGTH | INCHES MAXIMUM 1.840 |
| ADAT | BODY WIDTH | INCHES MAXIMUM 1.366 |
| ADAU | BODY HEIGHT | INCHES MAXIMUM 2.050 |
| AEHZ | MAXIMUM OPERATING TEMP | CELSIUS 65.0 |
| AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 1.185 |
| AKDX | WINDING QUANTITY | 1 |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AKPV | MOUNTING FACILITY QUANTITY | 2 |
| AXGY | MOUNTING METHOD | SINGLE GROUP THREADED HOLE(S) |
| BKPL | RATING METHOD | SINGLE COMPONENT SINGLE WINDING ELECTRICAL |
| CMLP | THREAD QUANTITY PER INCH | 32 |
| CQJX | NOMINAL THREAD SIZE | SINGLE GROUP INCHES 0.164 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT SINGLE WINDING AMPERES DC MAXIMUM 0.5 |
| CRGS | DC RESISTANCE RATING IN OHMS | 2.850 |
| THSD | THREAD SERIES DESIGNATOR | SINGLE GROUP UNIFIED NATIONAL COARSE (UNC) |
| TTQY | TERMINAL TYPE AND QUANTITY | SLOTTED LUG 2 |
Cross-references
6 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| 564071-000 | 56232 |
| APS 215 | 80223 |
| 5910PL1259638 | 9009H |
| 3154515 | 10001 |
| 5334 | 13483 |
| APS 215 | 15634 |