NSN 5950-01-101-3476 · NIIN 011013476 · FSC 5950
NO DASHES 5950011013476
In Stock
TRANSFORMER,POWER
Coils and Transformers
Technical characteristics
26 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 1.800 |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 1.800 |
| ACZB | FREQUENCY RATING | SINGLE COMPONENT HERTZ MINIMUM 47.0 AND HERTZ MAXIMUM 420.0 |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE |
| ACZX | WINDING SHIELDING METHOD | SINGLE COMPONENT INTERNAL SHIELD GROUNDED TO INCLOSURE AND BROUGHT OUT TO TERMINAL |
| ADAQ | BODY LENGTH | INCHES MAXIMUM 2.590 |
| ADAT | BODY WIDTH | INCHES MAXIMUM 2.120 |
| ADAU | BODY HEIGHT | INCHES MAXIMUM 1.690 |
| AEHZ | MAXIMUM OPERATING TEMP | CELSIUS 70.0 |
| AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
| AKPV | MOUNTING FACILITY QUANTITY | 4 |
| AXGY | MOUNTING METHOD | SINGLE GROUP THREADED HOLE(S) |
| BPLC | WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 2 AND SECONDARY 3 |
| CMLP | THREAD QUANTITY PER INCH | 40 |
| CQJX | NOMINAL THREAD SIZE | SINGLE GROUP INCHES 0.112 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT SECOND SECONDARY MILLIAMPERES AC MAXIMUM 220.0 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT THIRD SECONDARY MILLIAMPERES AC MAXIMUM 618.0 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT FIRST SECONDARY MILLIAMPERES AC MAXIMUM 220.0 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT ALL PRIMARY MILLIAMPERES AC MAXIMUM 54.0 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT ALL PRIMARY AC VOLTS NOMINAL 115.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 17.81 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 17.81 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT THIRD SECONDARY AC VOLTS NOMINAL 23.26 |
| THSD | THREAD SERIES DESIGNATOR | SINGLE GROUP UNIFIED NATIONAL COARSE (UNC) |
| TTQY | TERMINAL TYPE AND QUANTITY | PIN 12 |
Cross-references
3 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| 020-0770 | 31740 |
| 28101 | 07388 |
| 526-0447-010 | 13499 |