NSN 5950-01-156-4955 · NIIN 011564955 · FSC 5950
NO DASHES 5950011564955
In Stock
TRANSFORMER,POWER
Coils and Transformers
Technical characteristics
20 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 5.320 |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 4.280 |
| ABMK | OVERALL WIDTH | INCHES MAXIMUM 6.360 |
| ABTD | MOUNTING SLOT WIDTH | SINGLE GROUP INCHES NOMINAL 0.390 |
| ACZB | FREQUENCY RATING | SINGLE COMPONENT HERTZ MINIMUM 48.0 AND HERTZ MAXIMUM 420.0 |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE |
| ACZF | MAXIMUM TRANSFORMER POWER RATING | SINGLE COMPONENT KILOVOLT-AMPERE 2.65 |
| ACZX | WINDING SHIELDING METHOD | SINGLE COMPONENT INTERNAL SHIELD BROUGHT OUT TO TERMINAL |
| ADAQ | BODY LENGTH | INCHES MAXIMUM 6.570 |
| AEHZ | MAXIMUM OPERATING TEMP | CELSIUS 55.0 |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AKPV | MOUNTING FACILITY QUANTITY | 4 |
| AXGY | MOUNTING METHOD | SINGLE GROUP BRACKET(S) AND SLOT |
| BPLC | WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 2 AND SECONDARY 1 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT SINGLE SECONDARY AMPERES DC NOMINAL 22.0 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SECOND PRIMARY AC VOLTS NOMINAL 93.00 AND AC VOLTS NOMINAL 105.00 AND AC VOLTS NOMINAL 115.00 AND AC VOLTS NOMINAL 125.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE SECONDARY DC VOLTS NOMINAL 26.50 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 115.00 |
| TTQY | TERMINAL TYPE AND QUANTITY | TAB, SOLDER LUG 11 |