Technical characteristics
19 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABTB | MOUNTING HOLE DIAMETER | SINGLE GROUP INCHES NOMINAL 0.140 |
| ACZB | FREQUENCY RATING | SINGLE COMPONENT KILOHERTZ NOMINAL 20.0 |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE |
| ACZF | MAXIMUM TRANSFORMER POWER RATING | SINGLE COMPONENT WATTS 256.0 |
| ADAQ | BODY LENGTH | INCHES NOMINAL 2.200 |
| ADAT | BODY WIDTH | INCHES NOMINAL 2.200 |
| ADAU | BODY HEIGHT | INCHES NOMINAL 1.230 |
| AEHZ | MAXIMUM OPERATING TEMP | CELSIUS 130.0 |
| AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 1.800 |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AKPV | MOUNTING FACILITY QUANTITY | 2 |
| AXGY | MOUNTING METHOD | SINGLE GROUP UNTHREADED HOLE(S) |
| BPLC | WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND SECONDARY 2 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT FIRST SECONDARY MILLIAMPERES DC MAXIMUM 200.0 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 18.50 AND AC VOLTS NOMINAL 22.10 AND AC VOLTS NOMINAL 36.10 AND AC VOLTS NOMINAL 39.70 AND AC VOLTS NOMINAL 58.20 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 60.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 10.60 AND AC VOLTS NOMINAL 24.60 AND AC VOLTS NOMINAL 35.20 |
| TTQY | TERMINAL TYPE AND QUANTITY | PIN 14 |