| MRC | Requirement | Value |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 2.500 |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 2.000 |
| ACZB | FREQUENCY RATING | SINGLE COMPONENT HERTZ MINIMUM 50.0 AND HERTZ MAXIMUM 400.0 |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE |
| ACZX | WINDING SHIELDING METHOD | SINGLE COMPONENT INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE AND BROUGHT OUT TO TERMINAL |
| ADAQ | BODY LENGTH | INCHES NOMINAL 3.000 |
| ADAT | BODY WIDTH | INCHES NOMINAL 2.500 |
| ADAU | BODY HEIGHT | INCHES NOMINAL 4.625 |
| AEHZ | MAXIMUM OPERATING TEMP | CELSIUS 65.0 |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AKPV | MOUNTING FACILITY QUANTITY | 4 |
| AXGY | MOUNTING METHOD | SINGLE GROUP THREADED STUD(S) |
| BPLC | WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 2 AND SECONDARY 2 |
| CMLP | THREAD QUANTITY PER INCH | 32 |
| CQJX | NOMINAL THREAD SIZE | SINGLE GROUP INCHES 0.164 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT SECOND SECONDARY MILLIAMPERES DC MAXIMUM 205.0 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT FIRST SECONDARY MILLIAMPERES DC MAXIMUM 37.0 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 17.15 AND AC VOLTS NOMINAL 29.05 AND AC VOLTS NOMINAL 46.20 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 11.50 AND AC VOLTS NOMINAL 30.40 AND AC VOLTS NOMINAL 41.60 AND AC VOLTS NOMINAL 60.50 AND AC VOLTS NOMINAL 72.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT FIRST PRIMARY AC VOLTS NOMINAL 100.00 AND AC VOLTS NOMINAL 120.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SECOND PRIMARY AC VOLTS NOMINAL 120.00 |
| THSD | THREAD SERIES DESIGNATOR | SINGLE GROUP UNIFIED NATIONAL COARSE (UNC) |
| TTQY | TERMINAL TYPE AND QUANTITY | WIRE LEAD 20 |