NSN 5950-01-214-0565 · NIIN 012140565 · FSC 5950
NO DASHES 5950012140565
In Stock
TRANSFORMER,POWER
Coils and Transformers
Technical characteristics
19 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABTB | MOUNTING HOLE DIAMETER | SECOND GROUP INCHES NOMINAL 0.156 |
| ABTD | MOUNTING SLOT WIDTH | FIRST GROUP INCHES NOMINAL 0.156 |
| ACZB | FREQUENCY RATING | SINGLE COMPONENT HERTZ NOMINAL 400.0 |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE |
| ACZX | WINDING SHIELDING METHOD | SINGLE COMPONENT INTERNAL SHIELD BROUGHT OUT TO TERMINAL |
| ADAQ | BODY LENGTH | INCHES NOMINAL 2.090 |
| ADAT | BODY WIDTH | INCHES NOMINAL 1.500 |
| ADAU | BODY HEIGHT | INCHES NOMINAL 1.900 |
| AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | FIRST MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 1.125 |
| AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | SECOND MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 1.125 |
| AKNA | INCLOSURE TYPE | PARTIALLY INCLOSED |
| AKPV | MOUNTING FACILITY QUANTITY | 2 |
| AXGY | MOUNTING METHOD | SECOND GROUP UNTHREADED HOLE(S) |
| AXGY | MOUNTING METHOD | FIRST GROUP SLOT |
| BPLC | WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND SECONDARY 1 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT SINGLE PRIMARY AMPERES AC MAXIMUM 0.25 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY AC VOLTS MAXIMUM 20.00 |
| TTQY | TERMINAL TYPE AND QUANTITY | WIRE LEAD 5 |