NSN 5950-01-216-3639 · NIIN 012163639 · FSC 5950
NO DASHES 5950012163639
In Stock
TRANSFORMER,POWER
Coils and Transformers
Technical characteristics
27 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | THIRD MOUNTING FACILITY THIRD CENTER GROUP INCHES NOMINAL 13.750 |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | THIRD MOUNTING FACILITY THIRD CENTER GROUP INCHES NOMINAL 8.000 |
| ABTB | MOUNTING HOLE DIAMETER | SECOND GROUP INCHES NOMINAL 0.100 |
| ABTD | MOUNTING SLOT WIDTH | FIRST GROUP INCHES NOMINAL 0.568 |
| ACZB | FREQUENCY RATING | SINGLE COMPONENT HERTZ NOMINAL 60.0 |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE |
| ADAQ | BODY LENGTH | INCHES NOMINAL 15.250 |
| ADAT | BODY WIDTH | INCHES NOMINAL 12.250 |
| ADAU | BODY HEIGHT | INCHES NOMINAL 14.000 |
| AEHZ | MAXIMUM OPERATING TEMP | CELSIUS 220.0 |
| AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | SECOND MOUNTING FACILITY SECOND CENTER GROUP INCHES NOMINAL 10.000 |
| AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | FIRST MOUNTING FACILITY FIRST CENTER GROUP INCHES NOMINAL 10.000 |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AKPV | MOUNTING FACILITY QUANTITY | 2 |
| AKPV | MOUNTING FACILITY QUANTITY | 4 |
| AXGY | MOUNTING METHOD | THIRD GROUP THREADED HOLE(S) |
| AXGY | MOUNTING METHOD | FIRST GROUP SLOT |
| AXGY | MOUNTING METHOD | SECOND GROUP UNTHREADED HOLE(S) |
| BPLC | WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND SECONDARY 1 |
| CQJX | NOMINAL THREAD SIZE | THIRD GROUP INCHES 0.500 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT SINGLE SECONDARY AMPERES AC MAXIMUM 20.0 |
| CRMJ | WINDING POWER RATING | SINGLE COMPONENT SINGLE SECONDARY KILOVOLT-AMPERES 17.26 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY AC VOLTS MINIMUM 187.20 AND AC VOLTS MAXIMUM 228.80 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE SECONDARY AC VOLTS NOMINAL 863.00 |
| THSD | THREAD SERIES DESIGNATOR | THIRD GROUP UNIFIED NATIONAL COARSE (UNC) |
| TTQY | TERMINAL TYPE AND QUANTITY | WIRE LEAD 4 |