| MRC | Requirement | Value |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 2.625 |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 2.000 |
| ABTB | MOUNTING HOLE DIAMETER | SINGLE GROUP INCHES NOMINAL 0.156 |
| ACZB | FREQUENCY RATING | SINGLE COMPONENT KILOHERTZ NOMINAL 15.0 |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE |
| ADAQ | BODY LENGTH | INCHES MAXIMUM 3.000 |
| ADAT | BODY WIDTH | INCHES MAXIMUM 1.780 |
| ADAU | BODY HEIGHT | INCHES MAXIMUM 3.280 |
| AEHZ | MAXIMUM OPERATING TEMP | CELSIUS 130.0 |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AKPV | MOUNTING FACILITY QUANTITY | 4 |
| AXGY | MOUNTING METHOD | SINGLE GROUP UNTHREADED HOLE(S) |
| BPLC | WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 3 AND SECONDARY 5 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT FIRST SECONDARY AMPERES DC MAXIMUM 12.0 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT SECOND PRIMARY AMPERES AC MAXIMUM 0.5 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT THIRD SECONDARY AMPERES DC MINIMUM 15.0 AND AMPERES AC MAXIMUM 20.0 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT FOURTH SECONDARY AMPERES DC MINIMUM 2.3 AND AMPERES AC MAXIMUM 5.1 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT THIRD PRIMARY MILLIAMPERES AC MAXIMUM 10.0 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT FIRST PRIMARY MILLIAMPERES AC MAXIMUM 275.0 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT SECOND SECONDARY AMPERES DC MAXIMUM 6.0 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT FOURTH SECONDARY DC VOLTS NOMINAL 31.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT THIRD SECONDARY DC VOLTS NOMINAL 19.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT FIRST SECONDARY DC VOLTS NOMINAL 10.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SECOND PRIMARY AC VOLTS NOMINAL 8.48 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT THIRD PRIMARY AC VOLTS NOMINAL 57.55 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT FIRST PRIMARY AC VOLTS NOMINAL 268.66 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SECOND SECONDARY DC VOLTS NOMINAL 10.00 |
| FEAT | SPECIAL FEATURES | ALL SECONDARY OUTPUTS ARE DISPLAYED AS RECTIFIED VOLTAGES; 2ND SECONDARY PROVIDES A NEGATIVE VOLTAGE OUTPUT; SECONDARIES 3,4,5 PROVIDE POS AND NEG VOLTAGE OUTPUTS; 5TH SECONDARY OUTPUTS ARE POS 57.00 OR NEG 57.00 V DC W/ 0.5 AMPS MIN AND 1.0 AMPS MAX; 3 PRIMARY WINDINGS AND 5 SECONDARY WINDINGS |
| TTQY | TERMINAL TYPE AND QUANTITY | TAB, SOLDER LUG 24 |
Cross-references
6 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| 11780 | 55196 |
| 11780-4 | 55196 |
| 984717-4B | 82577 |
| 862398 | 82577 |
| 310-018388-01 | 95266 |
| 310-18721-01 | 95266 |