NSN 5950-01-230-9622 · NIIN 012309622 · FSC 5950
NO DASHES 5950012309622
In Stock
TRANSFORMER,POWER
Coils and Transformers
Technical characteristics
18 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABTB | MOUNTING HOLE DIAMETER | SINGLE GROUP INCHES NOMINAL 0.164 |
| ACZB | FREQUENCY RATING | SINGLE COMPONENT HERTZ NOMINAL 400.0 |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE |
| ACZF | MAXIMUM TRANSFORMER POWER RATING | SINGLE COMPONENT WATTS 2.2 |
| ACZX | WINDING SHIELDING METHOD | SINGLE COMPONENT INTERNAL SHIELD BROUGHT OUT TO TERMINAL |
| ADAQ | BODY LENGTH | INCHES MAXIMUM 1.120 |
| ADAR | BODY OUTSIDE DIAMETER | INCHES MAXIMUM 1.920 |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AKPV | MOUNTING FACILITY QUANTITY | 1 |
| AXGY | MOUNTING METHOD | SINGLE GROUP UNTHREADED HOLE(S) |
| BPLC | WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND SECONDARY 2 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT SECOND SECONDARY MILLIAMPERES AC MAXIMUM 8.4 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 14.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 115.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 27.20 AND AC VOLTS NOMINAL 30.00 AND AC VOLTS NOMINAL 33.30 |
| TEST | TEST DATA DOCUMENT | DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) 05869-732519 |
| TTQY | TERMINAL TYPE AND QUANTITY | TURRET 12 |