NSN 5950-01-245-2652 · NIIN 012452652 · FSC 5950
NO DASHES 5950012452652
In Stock
TRANSFORMER,POWER
Coils and Transformers
Technical characteristics
25 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABHP | OVERALL LENGTH | INCHES NOMINAL 3.000 |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 2.600 |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 2.600 |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 3.000 |
| ABMK | OVERALL WIDTH | INCHES NOMINAL 2.150 |
| ABTB | MOUNTING HOLE DIAMETER | SINGLE GROUP INCHES NOMINAL 0.156 |
| ACZB | FREQUENCY RATING | SINGLE COMPONENT KILOHERTZ NOMINAL 15.0 |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AKPV | MOUNTING FACILITY QUANTITY | 4 |
| AXGY | MOUNTING METHOD | SINGLE GROUP UNTHREADED HOLE(S) |
| BPLC | WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND SECONDARY 5 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT SECOND SECONDARY AMPERES AC MAXIMUM 1.5 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT FIFTH SECONDARY AMPERES AC MAXIMUM 1.0 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT FOURTH SECONDARY AMPERES AC MAXIMUM 130.0 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT THIRD SECONDARY AMPERES AC MAXIMUM 130.0 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT FIRST SECONDARY AMPERES AC MAXIMUM 1.5 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT FIFTH SECONDARY AC VOLTS NOMINAL 28.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT FOURTH SECONDARY AC VOLTS NOMINAL 14.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 372.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT THIRD SECONDARY AC VOLTS NOMINAL 14.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 7.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 7.00 |
| TTQY | TERMINAL TYPE AND QUANTITY | TAB, SOLDER LUG 18 |
Cross-references
4 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| 11881 | 55196 |
| 19878 | 72964 |
| H940045-001B | 82577 |
| 310-18436-01 | 95266 |