NSN 5950-01-312-7521 · NIIN 013127521 · FSC 5950
NO DASHES 5950013127521
In Stock
TRANSFORMER,POWER
Coils and Transformers
Technical characteristics
19 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABHP | OVERALL LENGTH | INCHES NOMINAL 4.031 |
| ABTB | MOUNTING HOLE DIAMETER | SINGLE GROUP INCHES NOMINAL 0.196 |
| ACZB | FREQUENCY RATING | SINGLE COMPONENT HERTZ NOMINAL 50.0 OR HERTZ NOMINAL 60.0 |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE |
| ADAT | BODY WIDTH | INCHES NOMINAL 2.562 |
| ADAU | BODY HEIGHT | INCHES NOMINAL 2.250 |
| AEHZ | MAXIMUM OPERATING TEMP | CELSIUS 130.0 |
| AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 3.562 |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AKPV | MOUNTING FACILITY QUANTITY | 2 |
| AXGY | MOUNTING METHOD | SINGLE GROUP UNTHREADED HOLE(S) |
| BPLC | WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND SECONDARY 1 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT SINGLE SECONDARY AMPERES AC NOMINAL 0.85 |
| CRMJ | WINDING POWER RATING | SINGLE COMPONENT SINGLE PRIMARY VOLTS-AMPERES 100.0 |
| CRMJ | WINDING POWER RATING | SINGLE COMPONENT SINGLE SECONDARY VOLTS-AMPERES 102.0 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 115.00 OR AC VOLTS NOMINAL 230.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE SECONDARY AC VOLTS NOMINAL 120.00 |
| TTQY | TERMINAL TYPE AND QUANTITY | TAB, SOLDER LUG 5 |
Cross-references
2 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| 4-07-8-120 | 19587 |
| 522356-1 | 80020 |