NSN 5950-01-330-9251 · NIIN 013309251 · FSC 5950
NO DASHES 5950013309251
In Stock
COIL,RADIO FREQUENCY
Coils and Transformers
Technical characteristics
20 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABHP | OVERALL LENGTH | INCHES MAXIMUM 1.000 |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES MINIMUM 0.690 AND INCHES MAXIMUM 0.710 |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES MINIMUM 0.440 AND INCHES MAXIMUM 0.460 |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 1.050 |
| ABMK | OVERALL WIDTH | INCHES MAXIMUM 0.750 |
| ACYV | INDUCTANCE RATING | SINGLE COMPONENT SINGLE WINDING MILLIHENRIES NOMINAL 3.25 |
| ACZP | COIL FORM TYPE | SINGLE COMPONENT SOLID |
| ACZR | CORE CONSTRUCTION | SINGLE COMPONENT S0LID |
| AEHZ | MAXIMUM OPERATING TEMP | CELSIUS 130.0 |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AKPV | MOUNTING FACILITY QUANTITY | 2 |
| AXGY | MOUNTING METHOD | SINGLE GROUP THREADED HOLE(S) |
| BKPL | RATING METHOD | SINGLE COMPONENT SINGLE WINDING ELECTRICAL |
| CQJX | NOMINAL THREAD SIZE | SINGLE GROUP INCHES 0.112 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT SINGLE WINDING MILLIAMPERES DC NOMINAL 500.0 |
| CRGS | DC RESISTANCE RATING IN OHMS | 0.600 |
| TEST | TEST DATA DOCUMENT | DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) 13973-841305 |
| THSD | THREAD SERIES DESIGNATOR | SINGLE GROUP UNIFIED NATIONAL COARSE (UNC) |
| TTQY | TERMINAL TYPE AND QUANTITY | PIN 2 |