NSN 5950-01-331-3922 · NIIN 013313922 · FSC 5950
NO DASHES 5950013313922
In Stock
TRANSFORMER,POWER
Coils and Transformers
Technical characteristics
24 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABHP | OVERALL LENGTH | INCHES MAXIMUM 4.560 |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES MINIMUM 2.990 AND INCHES MAXIMUM 3.010 |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES MINIMUM 2.990 AND INCHES MAXIMUM 3.010 |
| ABKW | OVERALL HEIGHT | INCHES MAXIMUM 2.270 |
| ABMK | OVERALL WIDTH | INCHES MAXIMUM 3.850 |
| ABTB | MOUNTING HOLE DIAMETER | SINGLE GROUP INCHES MINIMUM 0.181 AND INCHES MAXIMUM 0.201 |
| ACZB | FREQUENCY RATING | SINGLE COMPONENT HERTZ MINIMUM 45.0 AND HERTZ MAXIMUM 66.0 |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT THREE PHASE TO THREE PHASE |
| ACZD | TRANSFORMER WINDING CONNECTION TYPE | DELTA-DELTA |
| ACZX | WINDING SHIELDING METHOD | SINGLE COMPONENT INTERNAL SHIELD BROUGHT OUT TO TERMINAL |
| AEHZ | MAXIMUM OPERATING TEMP | CELSIUS 130.0 |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AKPV | MOUNTING FACILITY QUANTITY | 4 |
| AXGY | MOUNTING METHOD | SINGLE GROUP UNTHREADED HOLE(S) |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT SECOND SECONDARY MILLIAMPERES AC NOMINAL 500.0 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT FIRST SECONDARY AMPERES AC NOMINAL 1.75 |
| CRMJ | WINDING POWER RATING | SINGLE COMPONENT FIRST SECONDARY VOLTS-AMPERES 16.6 |
| CRMJ | WINDING POWER RATING | SINGLE COMPONENT SECOND SECONDARY VOLTS-AMPERES 7.42 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 14.85 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 208.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 9.50 |
| TEST | TEST DATA DOCUMENT | DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) 13973-841355 |
| TTQY | TERMINAL TYPE AND QUANTITY | TAB, SOLDER LUG 10 |
Cross-references
7 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| 43829-1 | 22558 |
| WE-4155 | 26543 |
| C15300 | 72149 |
| 311-14834-01 | 95266 |
| PEI 7991 | 13483 |
| WE-4155 | 15634 |
| 841355-0001 | 13973 |