| MRC | Requirement | Value |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 2.250 |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 2.812 |
| ABTD | MOUNTING SLOT WIDTH | SINGLE GROUP INCHES NOMINAL 0.203 |
| ACZB | FREQUENCY RATING | SINGLE COMPONENT HERTZ NOMINAL 50.0 OR HERTZ NOMINAL 60.0 |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE |
| ACZX | WINDING SHIELDING METHOD | SINGLE COMPONENT INTERNAL SHIELD GROUNDED TO CORE |
| ADAQ | BODY LENGTH | INCHES NOMINAL 3.688 |
| ADAT | BODY WIDTH | INCHES NOMINAL 3.375 |
| ADAU | BODY HEIGHT | INCHES NOMINAL 2.812 |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AKPV | MOUNTING FACILITY QUANTITY | 4 |
| AXGY | MOUNTING METHOD | SINGLE GROUP SLOT |
| BPLC | WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 2 AND SECONDARY 2 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT SECOND SECONDARY AMPERES AC NOMINAL 3.0 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT FIRST SECONDARY AMPERES AC NOMINAL 2.0 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 34.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 16.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT ALL PRIMARY AC VOLTS NOMINAL 115.00 |
| TTQY | TERMINAL TYPE AND QUANTITY | WIRE LEAD 10 |