NSN 5950-01-369-7573 · NIIN 013697573 · FSC 5950
NO DASHES 5950013697573
In Stock
TRANSFORMER,POWER
Coils and Transformers
Technical characteristics
19 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | ALL MOUNTING FACILITIES ALL CENTER GROUPINGS INCHES NOMINAL 4.000 |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | ALL MOUNTING FACILITIES ALL CENTER GROUPINGS INCHES NOMINAL 4.000 |
| ABTB | MOUNTING HOLE DIAMETER | SINGLE GROUP INCHES MINIMUM 0.187 AND INCHES MAXIMUM 0.196 |
| ACZB | FREQUENCY RATING | ALL COMPONENTS HERTZ NOMINAL 60.0 |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE |
| ADAQ | BODY LENGTH | INCHES NOMINAL 4.500 |
| ADAT | BODY WIDTH | INCHES NOMINAL 4.500 |
| ADAU | BODY HEIGHT | INCHES MAXIMUM 1.750 |
| AEHZ | MAXIMUM OPERATING TEMP | CELSIUS 75.0 |
| AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | ALL MOUNTING FACILITIES ALL CENTER GROUPINGS INCHES NOMINAL 4.000 |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AKPV | MOUNTING FACILITY QUANTITY | 4 |
| AXGY | MOUNTING METHOD | ALL GROUPINGS UNTHREADED HOLE(S) |
| BPLC | WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND SECONDARY 1 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT SINGLE SECONDARY MILLIAMPERES AC MAXIMUM 10.0 |
| TEST | TEST DATA DOCUMENT | DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) 09004-116382 |
| TTQY | TERMINAL TYPE AND QUANTITY | WIRE LEAD 4 |
| ZZZK | SPECIFICATION/STANDARD DATA | MANUFACTURERS SOURCE CONTROL 09004-116382 |