NSN 5950-01-369-9021 · NIIN 013699021 · FSC 5950
NO DASHES 5950013699021
In Stock
TRANSFORMER,POWER
Coils and Transformers
Technical characteristics
30 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | ALL MOUNTING FACILITIES ALL CENTER GROUPINGS INCHES NOMINAL 4.260 |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | ALL MOUNTING FACILITIES ALL CENTER GROUPINGS INCHES NOMINAL 1.760 |
| ACZB | FREQUENCY RATING | SECOND COMPONENT KILOHERTZ NOMINAL 50.0 |
| ACZB | FREQUENCY RATING | FIRST COMPONENT KILOHERTZ NOMINAL 50.0 |
| ACZB | FREQUENCY RATING | THIRD COMPONENT KILOHERTZ MINIMUM 10.0 AND KILOHERTZ MAXIMUM 100.0 |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | ALL COMPONENTS SINGLE PHASE TO SINGLE PHASE |
| ACZX | WINDING SHIELDING METHOD | FIRST COMPONENT INTERNAL SHIELD BROUGHT OUT TO TERMINAL |
| ACZX | WINDING SHIELDING METHOD | SECOND COMPONENT INTERNAL SHIELD BROUGHT OUT TO TERMINAL |
| ADAQ | BODY LENGTH | INCHES MAXIMUM 4.800 |
| ADAT | BODY WIDTH | INCHES MAXIMUM 2.380 |
| ADAU | BODY HEIGHT | INCHES MAXIMUM 2.380 |
| AEHZ | MAXIMUM OPERATING TEMP | CELSIUS 70.0 |
| AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | SECOND MOUNTING FACILITY ALL CENTER GROUPINGS INCHES NOMINAL 1.760 |
| AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | FIRST MOUNTING FACILITY ALL CENTER GROUPINGS INCHES NOMINAL 4.260 |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AKPV | MOUNTING FACILITY QUANTITY | 4 |
| AXGY | MOUNTING METHOD | ALL GROUPINGS THREADED HOLE(S) |
| BPLC | WINDING FUNCTION AND QUANTITY | ALL COMPONENTS PRIMARY 4 AND CONTROL 2 AND SECONDARY 8 |
| CQJX | NOMINAL THREAD SIZE | ALL GROUPINGS INCHES 0.138 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT SECOND SECONDARY AMPERES AC MAXIMUM 1.1 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT FIRST SECONDARY AMPERES AC MAXIMUM 3.3 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT FOURTH SECONDARY AMPERES AC MAXIMUM 1.15 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT THIRD SECONDARY AMPERES AC MAXIMUM 2.15 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SECOND PRIMARY AC VOLTS MINIMUM 26.00 AND AC VOLTS MAXIMUM 35.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT FIRST PRIMARY AC VOLTS MINIMUM 26.00 AND AC VOLTS MAXIMUM 35.00 |
| FEAT | SPECIAL FEATURES | 200:1CURRENT TRANSFORMER AND FLYBACK TRANSFORMER |
| THSD | THREAD SERIES DESIGNATOR | ALL GROUPINGS UNIFIED NATIONAL COARSE (UNC) |
| TTQY | TERMINAL TYPE AND QUANTITY | TURRET 22 |
| ZZZK | SPECIFICATION/STANDARD DATA | MANUFACTURERS SOURCE CONTROL 09004-34931 |