Technical characteristics
25 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SECOND MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 1.100 |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | FIRST MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 1.240 |
| ABTB | MOUNTING HOLE DIAMETER | SINGLE GROUP INCHES NOMINAL 0.120 |
| ACZB | FREQUENCY RATING | SINGLE COMPONENT HERTZ NOMINAL 50.0 OR HERTZ NOMINAL 60.0 |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE |
| ACZF | MAXIMUM TRANSFORMER POWER RATING | ALL COMPONENTS WATTS 8.0 |
| ACZX | WINDING SHIELDING METHOD | SINGLE COMPONENT INTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL AND INTERNAL SHIELD BROUGHT OUT TO TERMINAL |
| ADAQ | BODY LENGTH | INCHES MAXIMUM 1.943 |
| ADAT | BODY WIDTH | INCHES MAXIMUM 1.623 |
| ADAU | BODY HEIGHT | INCHES MAXIMUM 1.440 |
| AEHZ | MAXIMUM OPERATING TEMP | CELSIUS 70.0 |
| AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | FIRST MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 1.240 |
| AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | SECOND MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 1.100 |
| AKNA | INCLOSURE TYPE | OPEN |
| AKPV | MOUNTING FACILITY QUANTITY | 14 |
| AXGY | MOUNTING METHOD | ALL GROUPINGS TERMINAL OR UNTHREADED HOLE(S) |
| BPLC | WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 2 AND SECONDARY 2 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT ALL PRIMARY MILLIAMPERES AC MAXIMUM 53.3 |
| CRMJ | WINDING POWER RATING | SINGLE COMPONENT ALL PRIMARY WATTS 8.0 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT FIRST SECONDARY DC VOLTS MAXIMUM 22.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SECOND SECONDARY DC VOLTS MINIMUM 7.50 AND DC VOLTS MAXIMUM 8.20 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT ALL PRIMARY AC VOLTS NOMINAL 115.00 |
| TEST | TEST DATA DOCUMENT | DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) 80164-TR-201 |
| TTQY | TERMINAL TYPE AND QUANTITY | PIN 10 |
Cross-references
1 manufacturer part number on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| TR-201 | 80164 |