NSN 5950-01-372-8516 · NIIN 013728516 · FSC 5950
NO DASHES 5950013728516
In Stock
TRANSFORMER,POWER
Coils and Transformers
Technical characteristics
19 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 5.750 |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 9.750 |
| ABTB | MOUNTING HOLE DIAMETER | ALL GROUPINGS INCHES NOMINAL 0.375 |
| ACZB | FREQUENCY RATING | SINGLE COMPONENT HERTZ NOMINAL 60.0 |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE |
| ACZF | MAXIMUM TRANSFORMER POWER RATING | SINGLE COMPONENT KILOVOLT-AMPERE 3.0 |
| ADAQ | BODY LENGTH | INCHES NOMINAL 7.688 |
| ADAT | BODY WIDTH | INCHES NOMINAL 6.875 |
| ADAU | BODY HEIGHT | INCHES NOMINAL 10.875 |
| AKNA | INCLOSURE TYPE | PARTIALLY INCLOSED, DOUBLE SHELL |
| AKPV | MOUNTING FACILITY QUANTITY | 4 |
| AXGY | MOUNTING METHOD | SINGLE GROUP UNTHREADED HOLE(S) |
| BFMF | COOLING METHOD | SELF-COOLED |
| BPLC | WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 2 AND SECONDARY 2 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT ALL SECONDARY AMPERES AC MAXIMUM 25.0 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT ALL SECONDARY AC VOLTS NOMINAL 120.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT ALL PRIMARY AC VOLTS NOMINAL 240.00 |
| TTQY | TERMINAL TYPE AND QUANTITY | WIRE LEAD 8 |
Cross-references
1 manufacturer part number on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| 80-1050 | 18284 |