NSN 5985-01-518-2626 · NIIN 015182626 · FSC 5985
NO DASHES 5985015182626
In Stock
DUMMY LOAD,ELECTRICAL
Antennas, Waveguides, and Related Equipment
Technical characteristics
7 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ACYW | IMPEDANCE RATING IN OHMS | NOMINAL 50.0 |
| AJDB | POWER RATING | KILOWATTS AVERAGE 50.000 |
| AKRZ | TERMINATION TYPE | CONNECTOR |
| BFMF | COOLING METHOD | FORCED LIQUID |
| FEAT | SPECIAL FEATURES | AC POWER REQUIREMENTS 230 VAC, SINGLE PHASE 27.5 AMP; 208-230/460 VAC, THREE PHASE 9.6/4.8 AMP; FINISH BEIGE SPLATTER; FAN 1.5 HP CENTRIFUGAL; PUMP 1.5 HP CENTRIFUGAL; VSWR 60 HZ TO 800MHZ 1.1:1 MAX |
| FTLD | FUNCTIONAL DESCRIPTION | MODEL 5850 RF HEAT EXCHANGER IS A MODEL 9750 50 OHM RESISTOR ASSEMBLY COOLED BY A VENTED, CLOSED-LOOP WATER SYSTEM, UTILIZING A CENTRIFUGAL PUMP, WATER-TO-AIR HEAT EXCHANGER, CAPACITY OF COOLANT IS APPROX 11 US GALLONS, AND 1 CENTRIFUGAL BLOWER; BLOWER ASSY IS A 1.5 HP BELT-DRIVEN CENTRIFUGAL BLOWER, BLOWER MOVES AIR INTO A CLOSED PLENUM, THROUGH THE HEAT EXCHANGER COIL TO THE REAR OF UNIT |
| SUPP | SUPPLEMENTARY FEATURES | LOCATION SHOULD BE DRY, FREE OF EXCESSIVE DUST AND AMBIENT TEMP P5.0 TO 35 DEG C WITH WATER ONLY AND M20.0 TO 30.0 DEG C WITH PORM 35 PCT ETHYLENE GLYCOL MIXTURE; ROOM WELL VENTILATED; RF DISSIPATION OF UNIT IS 50,000 WATTS EQUALS 170.650 BTU/HR USUALLY DUCTED OUT OF BUILDING; NOT NECESSARY TO MOUNT WHICH IS DESIGNED TO BE A FREE-STANDING DEVICE RESTING ON 4 HEAVY DUTY CASTERS; BRAKES ARE INSTALLED ON SWIVEL CASTERS; 4 TERMINAL, CAPTIVE-SCREW TERMINAL STRIP |
Cross-references
1 manufacturer part number on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| 5850 | 27430 |