Home / MS parts / NSN 5996-01-361-4972
NSN 5996-01-361-4972  ·  NIIN 013614972  ·  FSC 5996
NO DASHES 5996013614972
In Stock

AMPLIFIER,RADIO FREQUENCY

Amplifiers

Technical characteristics

25 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
ABHPOVERALL LENGTHINCHES NOMINAL 21.240
ABKWOVERALL HEIGHTINCHES NOMINAL 3.500
ABMKOVERALL WIDTHINCHES NOMINAL 18.240
AFGAOPERATING TEMP RANGECELSIUS 0.0 TO 50.0
AFSUAVERAGE LIFE MEASUREMENTNOT RATED
AGTABASIC SHAPE STYLE
AKAEMAXIMUM OPERATING ALTITUDE RATINGFEET 10000.0
AKNAINCLOSURE TYPEENCASED
ALBMOPERATING CONTROL METHODMANUAL
AMQYINSTALLATION DESIGNTOP OF CABINET/COUNTER AND RACK
AQZFCONTROL TYPELOCAL
AWLSCONNECTION TYPEFRONT TERMINAL STUD
BHSXCIRCUIT CONSTRUCTION TYPESOLID STATE
BHTBFREQUENCY PER CHANNELGIGAHERTZ NOMINAL OPERATING CHANNEL 4.0 AND GIGAHERTZ NOMINAL OPERATING CHANNEL 8.0
BHTJAVERAGE POWER RATING PER CHANNELWATTS OUTPUT 10.0
BHTLOVERALL GAINDECIBELS 30.0
BJBQOPERATING AC FREQUENCY IN HERTZMINIMUM SINGLE VOLTAGE 47.0 AND MAXIMUM SINGLE VOLTAGE 63.0
BJBRMAXIMUM POWER DRAIN RATINGWATTS 250.0
BJBWCONNECTION CONTACT TYPE AND QUANTITYCOAXIAL RECEPTACLE INTERNAL 1
BKFCEXTERNAL AC OPERATING VOLTAGE IN VOLTSMINIMUM SINGLE VOLTAGE 99.0 AND MAXIMUM SINGLE VOLTAGE 132.0
CBMECUBIC MEASURECUBIC FEET 0.73
CQSJINCLOSURE MATERIALALUMINUM
FAAZPHASESINGLE
FEATSPECIAL FEATURESFRONT PANEL CONTROLS: PRIME POWER ON/OFF,RF OPERATE/STANDBY (FAULT RESET). FRONT PANEL INDICATORS: PRIME POWER ON/STANDBY,RF OPERATE,FAULT. METERING: HELIX CURRENT. PROTECTION: PRIME POWER FUSE,WARM UP DELAY,AUTOMATIC SEQUENCING OF HIGH VOLTAGE AND BEAM CURRENT,UNATTENDED PROTECTION (HEATER SHUTDOWN AFTER FAULT COUNTER TRIP),HELIX CURRENT OVERLOAD,HIGH TEMPERATURE LOW/HIGH LINE VOLTAGE,SAFETY INTERLOCKS. EQUIPMENT CASE,IS A SELF-CONTAINED DESIGNED FOR BENCH TOP OR RACK MOUNT. AUTO RECYCLE IF POWER OUTAGE IS LESSTHAN 3 SECONDS. AUTOMATIC TURN OFF IF TWO CONSECUTIVE HELIX OVERLOAD FAULTS OCCUR:NOISE FIGURE 35DB MAX: SPURIOUS MODULATION M50DBC MAX: LOAD VSWR 2.5:1 MAX: GAIN STABILITY 0.25DB/24HRS: MAXOPERATING HUMIDITY 95PCT
RTSERELATIONSHIP TO SIMILAR EQUIPMENT6625010346118

Cross-references

2 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.

Manufacturer cross-reference part numbers and CAGE codes
Manufacturer part numberCAGE
8010H02F0001L7Y9
8010H02F00073293