NSN 6105-00-295-0959 · NIIN 002950959 · FSC 6105
NO DASHES 6105002950959
In Stock
MOTOR,ALTERNATING CURRENT
Motors, Electrical
Technical characteristics
27 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| FREQ | FREQUENCY IN HERTZ | 60.0 |
| AXGY | MOUNTING METHOD | FIXED BASE |
| AAJT | OVERALL HEIGHT | INCHES 24.906 |
| AAJU | OVERALL LENGTH | INCHES 42.375 |
| AAJV | OVERALL WIDTH | INCHES 25.188 |
| CBBL | FEATURES PROVIDED | HORIZONTAL MOUNTING POSITION |
| CWCS | LENGTH OF SHAFT FROM HOUSING | FIRST END INCHES 4.750 |
| AKCT | SHAFT ROTATION DIRECTION | SECOND END COUNTERCLOCKWISE |
| AKPS | DUTY CYCLE | INTERMITTENT |
| AKCT | SHAFT ROTATION DIRECTION | FIRST END CLOCKWISE |
| FAAZ | PHASE | INPUT THREE |
| AXCP | WINDING TYPE | INDUCTION-SQUIRREL CAGE |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | UNTHREADED HOLE(S) 4 |
| BFMF | COOLING METHOD | NATURAL CONVECTION VENTILATED |
| BKPB | CURRENT RATING METHOD | LOAD |
| BKPQ | INCLOSURE SPECIFICATION | MIL-STD-108 |
| BTBY | SHAFT END STYLE | |
| BYDT | BEARING TYPE | ANNULAR BALL |
| CWCS | LENGTH OF SHAFT FROM HOUSING | SECOND END INCHES 6.750 |
| CWDT | NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | INCHES 16.500 |
| CWDY | TEMP RATING | OPERATING CELSIUS 40.0 |
| CWFY | NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | INCHES 18.000 |
| CWGQ | CONNECTION TYPE AND VOLTAGE RATING IN VOLTS | INPUT LINE TO NEUTRAL SINGLE 440.0 |
| ANPZ | ENCLOSURE FEATURE | DRIPPROOF PROTECTED-15 DEG |
| ANTN | SPECIFIC USE | HANGAR DIVISION DOORS |
| TTQY | TERMINAL TYPE AND QUANTITY | SOLDER LUG 6 |
| TEST | TEST DATA DOCUMENT | SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL---17060 |