NSN 6105-00-635-9505 · NIIN 006359505 · FSC 6105
NO DASHES 6105006359505
In Stock
MOTOR,DIRECT CURRENT
Motors, Electrical
Technical characteristics
21 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AAJV | OVERALL WIDTH | INCHES 9.020 |
| CWGQ | CONNECTION TYPE AND VOLTAGE RATING IN VOLTS | INPUT LINE TO NEUTRAL SINGLE 57.0 |
| TTQY | TERMINAL TYPE AND QUANTITY | THREADED STUD 3 |
| CWGL | CURRENT RATING IN AMPS | INPUT SINGLE 192.000 |
| AAJU | OVERALL LENGTH | INCHES 14.320 |
| ABWV | SHAFT DIAMETER | SINGLE END INCHES NOMINAL 0.7500 |
| AKCT | SHAFT ROTATION DIRECTION | SINGLE END CLOCKWISE |
| AKPS | DUTY CYCLE | INTERMITTENT |
| ANPZ | ENCLOSURE FEATURE | OPEN |
| AXCP | WINDING TYPE | COMPOUND WOUND |
| BKPQ | INCLOSURE SPECIFICATION | MIL-STD-108 |
| CNMK | WOODRUFF KEY SIZE DESIGNATION | 404 |
| CNXS | POWER RATING | OUTPUT HORSEPOWER 11.5000 |
| CWCS | LENGTH OF SHAFT FROM HOUSING | SINGLE END INCHES 0.785 |
| CWDY | TEMP RATING | OPERATING CELSIUS 0.0 AND OPERATING CELSIUS 30.0 |
| CWFX | ROTOR SPEED RATING IN RPM | SINGLE FULL LOAD 2600.0 |
| BFMF | COOLING METHOD | NATURAL CONVECTION VENTILATED |
| BKPB | CURRENT RATING METHOD | LOAD |
| AAJT | OVERALL HEIGHT | INCHES 9.020 |
| CWHZ | SHAFT END CHARACTERISTIC | SINGLE END SINGLE STYLE A11 |
| FEAT | SPECIAL FEATURES | 2 ROWS OF 3 EACH RUBBER SHOCK MOUNTS EQUALLY SPACED AROUNDWINDING HOUSING |