NSN 6105-01-366-2111 · NIIN 013662111 · FSC 6105
NO DASHES 6105013662111
In Stock
MOTOR,ALTERNATING CURRENT
Motors, Electrical
Technical characteristics
26 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AAJT | OVERALL HEIGHT | INCHES 9.250 |
| AAJU | OVERALL LENGTH | INCHES 16.290 |
| AAJV | OVERALL WIDTH | INCHES 11.750 |
| AASA | THREAD LENGTH | FIRST END INCHES NOMINAL 0.500 |
| ABRR | KEYWAY WIDTH | SECOND END INCHES NOMINAL 0.126 |
| ABRV | KEYWAY DEPTH | SECOND END INCHES NOMINAL 0.505 |
| ABWV | SHAFT DIAMETER | FIRST END INCHES NOMINAL 0.875 |
| AFYS | KEYWAY LENGTH | SECOND END INCHES NOMINAL 0.260 |
| AKPS | DUTY CYCLE | CONTINUOUS |
| ANPZ | ENCLOSURE FEATURE | TOTALLY ENCLOSED |
| AXCP | WINDING TYPE | INDUCTION-SQUIRREL CAGE |
| AXGY | MOUNTING METHOD | FIXED BASE |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | UNTHREADED HOLE(S) 4 |
| BFMF | COOLING METHOD | AMBIENT AIR |
| BKPQ | INCLOSURE SPECIFICATION | COMMERCIAL |
| BTBY | SHAFT END STYLE | |
| CNMM | FRAME SIZE DESIGNATION | 102T |
| CNXS | POWER RATING | OUTPUT HORSEPOWER 1.500 |
| CWCS | LENGTH OF SHAFT FROM HOUSING | SECOND END INCHES 2.125 |
| CWCS | LENGTH OF SHAFT FROM HOUSING | FIRST END INCHES 2.690 |
| CWDT | NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | INCHES 4.500 |
| CWFY | NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | INCHES 7.500 |
| CWGQ | CONNECTION TYPE AND VOLTAGE RATING IN VOLTS | INPUT LINE TO NEUTRAL SINGLE 440.0 |
| FAAZ | PHASE | INPUT THREE |
| FREQ | FREQUENCY IN HERTZ | 60.0 |
| TTQY | TERMINAL TYPE AND QUANTITY | SOLDERLESS LUG 3 |
Cross-references
5 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| 01-0212.1 | 20019 |
| 01-0212 | 20019 |
| B5452 | 28953 |
| A107-C2068 | 28953 |
| A7465 | 28953 |