NSN 6110-00-397-3832 · NIIN 003973832 · FSC 6110
NO DASHES 6110003973832
In Stock
CONTROLLER,MOTOR
Electrical Control Equipment
Technical characteristics
22 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ANDX | AMBIENT TEMP | CELSIUS 50.0 |
| ANCY | HORSEPOWER RATING | 25.000 |
| ANDG | FUSE CURRENT RATING IN AMPS | 10.0 |
| AKPS | DUTY CYCLE | CONTINUOUS |
| ALGC | MOUNTING CONFIGURATION | FOUR 17/32 IN. DIA MTG HOLES ON 18.000 IN. BY 12.500 IN. MTG CTR |
| ANCN | OPERATING VOLTAGE CHARACTERISTIC | FULL |
| ACYN | AC VOLTAGE RATING | VOLTS NOMINAL 440.0 |
| ACZB | FREQUENCY RATING | HERTZ NOMINAL 60.0 |
| FREQ | FREQUENCY IN HERTZ | 60.0 |
| ABHP | OVERALL LENGTH | INCHES NOMINAL 20.120 |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 8.000 |
| CBBL | FEATURES PROVIDED | CIRCUIT PROTECTION FUSE |
| FAAZ | PHASE | THREE |
| AJXE | SIZE DESIGNATOR | 2 |
| ABMK | OVERALL WIDTH | INCHES NOMINAL 16.100 |
| ANPZ | ENCLOSURE FEATURE | DRIPPROOF |
| ANQC | NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION STANDARDS DESIGN | DESIGNED PER NEMA STD |
| ANRK | SWITCH FUNCTIONAL POSITIONS | EMERGENCY RUN |
| AQZF | CONTROL TYPE | LOCAL OR REMOTE |
| AFLW | ACTUATION METHOD | MAGNETIC |
| AGUE | FUSE ACCOMMODATION QUANTITY | 2 |
| ABBB | SPEED ADJUSTMENTS | TWO SPEED |
Cross-references
3 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| 6968ED415A2 | 27192 |
| 6968ED415B2 | 27192 |
| 6968ED415 | 27192 |