NSN 6110-00-635-7125 · NIIN 006357125 · FSC 6110
NO DASHES 6110006357125
In Stock
STARTER,MOTOR
Electrical Control Equipment
Application: INSTRUCTION BOOK NO. NAVSHIPS 359-0243
Technical characteristics
23 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| CBBL | FEATURES PROVIDED | CIRCUIT PROTECTION FUSE |
| ANCQ | FULL VOLTAGE RESTORING METHOD | CURRENT LIMIT ACCELERATION |
| AFLW | ACTUATION METHOD | MAGNETIC |
| ABBB | SPEED ADJUSTMENTS | SINGLE SPEED |
| ZZZT | NONDEFINITIVE SPEC/STD DATA | SIZE 2 |
| AQZF | CONTROL TYPE | LOCAL |
| ABMK | OVERALL WIDTH | INCHES NOMINAL 21.500 |
| AGAV | END ITEM IDENTIFICATION | INSTRUCTION BOOK NO. NAVSHIPS 359-0243 |
| AGLD | PERFORMANCE TYPE | AUTOMATIC |
| AGUE | FUSE ACCOMMODATION QUANTITY | 2 |
| AKPS | DUTY CYCLE | CONTINUOUS |
| ALGC | MOUNTING CONFIGURATION | SIX 21/32 IN. DIA MTG HOLES ARRANGED IN 2 ROWS OF 3 HOLES EA W/26 IN. BETWEEN ROWS AND HOLES ON 8-1/4 IN.,8-3/4 IN. MTG CENTERS |
| ANCN | OPERATING VOLTAGE CHARACTERISTIC | REDUCED |
| ANDE | ACTUATOR VOLTAGE | DC 230.0 |
| ANDW | LOAD PROTECTION TYPE | OVERLOAD OR UNDERVOLTAGE |
| ANDX | AMBIENT TEMP | CELSIUS 50.0 |
| ANPZ | ENCLOSURE FEATURE | DRIPPROOF |
| ANRK | SWITCH FUNCTIONAL POSITIONS | AUTOMATIC AND EMERGENCY AND MANUAL AND START AND STOP |
| ABHP | OVERALL LENGTH | INCHES NOMINAL 29.000 |
| ANCP | VOLTAGE REDUCTION METHOD | RESISTOR |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 11.500 |
| CNXS | POWER RATING | HORSEPOWER 7.500 |
| FEAT | SPECIAL FEATURES | W/INTEGRAL MANUAL, ACROSS THE LINE, STARTER FOR USE W/.5 HP CONDENSER COOLING WATER PUMP MOTOR |
Cross-references
3 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| 6942ED1688A2 | 27192 |
| MILC2212 | 81349 |
| 6942ED71DUPLEX | 15605 |