NSN 6110-01-145-2746 · NIIN 011452746 · FSC 6110
NO DASHES 6110011452746
In Stock
STARTER,MOTOR
Electrical Control Equipment
Technical characteristics
22 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ABBB | SPEED ADJUSTMENTS | 0 TO FULL SPEED |
| ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | DRIPPROOF |
| ABHP | OVERALL LENGTH | INCHES NOMINAL 17.125 |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 9.093 |
| ABMK | OVERALL WIDTH | INCHES NOMINAL 8.875 |
| ACYN | AC VOLTAGE RATING | VOLTS NOMINAL 440.0 |
| ACZB | FREQUENCY RATING | HERTZ NOMINAL 60.0 |
| AFLW | ACTUATION METHOD | MAGNETIC |
| AGLD | PERFORMANCE TYPE | AUTOMATIC |
| AJXE | SIZE DESIGNATOR | 0 |
| AKPS | DUTY CYCLE | CONTINUOUS |
| ALGC | MOUNTING CONFIGURATION | FOUR 15/32 IN. DIA HOLES ON 6-3/4 IN. BY 12-1/2 IN. RECTANGULAR CENTERS |
| ANCN | OPERATING VOLTAGE CHARACTERISTIC | FULL |
| ANDE | ACTUATOR VOLTAGE | AC 115.0 |
| ANDW | LOAD PROTECTION TYPE | OVERLOAD OR UNDERVOLTAGE |
| ANDX | AMBIENT TEMP | CELSIUS 50.0 |
| ANPZ | ENCLOSURE FEATURE | DRIPPROOF |
| ANQC | NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION STANDARDS DESIGN | DESIGNED PER NEMA STD |
| ANRK | SWITCH FUNCTIONAL POSITIONS | EMERGENCY RUN AND OVERLOAD RESET |
| AQZF | CONTROL TYPE | LOCAL OR REMOTE |
| FAAZ | PHASE | THREE |
| FREQ | FREQUENCY IN HERTZ | 60.0 |
Cross-references
1 manufacturer part number on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| 24103 | 63743 |