NSN 6115-01-562-4525 · NIIN 015624525 · FSC 6115
NO DASHES 6115015624525
In Stock
GENERATOR SET,DIESEL ENGINE,TRAI
Generators and Generator Sets, Electrical
Application: PU-2005
Technical characteristics
11 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AYGY | AC WATTAGE RATING | KILOWATTS 60.0 AND KILOWATTS 50.0 |
| AGAV | END ITEM IDENTIFICATION | PU-2005 |
| ABFF | FURNISHED ITEMS | WINTERIZATION |
| ACDC | CURRENT TYPE | AC |
| ACZB | FREQUENCY RATING | HERTZ NOMINAL 60.0 AND HERTZ NOMINAL 50.0 |
| RTSE | RELATIONSHIP TO SIMILAR EQUIPMENT | 60KW AMMPS POWER UNIT WILL REPLACE THE 60KW TQG POWER UNIT |
| FTLD | FUNCTIONAL DESCRIPTION | AMMPS POWER UNIT PU-2005 CONSIST OF ONE MEP-1070 GENERATOR SET, DIESEL ENGINE DRIVEN, JP-8 FUEL, STANDARD MILITARY FUEL, LUBRICANTS AND COOLANTS, CLASS 2-B UTILITY, MOUNTED ON A MONDIFIED LTT TRAILER, SECURE TO TRANSPORT |
| FEAT | SPECIAL FEATURES | TRAILER MOUNTED GENERATOR SET THAT PRODUCES 60KW (60HZ) 50KW (50HZ) OF CONTINUOUS POWER AT 0.8 PF AT 4000 FT ELEVATION AT 95 DEGREE F, CAPABLE OF 50 OR 60 HZ OPERATION AND 3 PHASE 120/208 VAC OR 3 PHASE 240/416-VAC OUTPUT, OPERATE FROM -50 DEGREES F (WIHT WINTERIZATION KIT, OR -25 DEGREE F WITHOUT) TO 135 DEGREES F |
| AYHD | POWER FACTOR IN PERCENT | 0.8 |
| CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | GENERATOR SET, DIESEL ENGINE, TRAILER MOUNTED |
| FAAZ | PHASE | THREE |