NSN 6120-01-523-8591 · NIIN 015238591 · FSC 6120
NO DASHES 6120015238591
In Stock
POWER SUPPLY
Transformers: Distribution and Power Station
Application: AID CONTROL AND MONITOR SYSTEM (1SG38-ACMS)
Technical characteristics
17 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| FEAT | SPECIAL FEATURES | RIPPLE VOLTAGE-2 PERCENT P-P MAXIMUM (INCLUDING NOISE) |
| BGQR | OUTPUT WATTAGE RATING | SINGLE POWER OUTPUT WATTS NOMINAL 15.0 |
| CWGH | OUTPUT CURRENT RATING | SINGLE POWER OUTPUT DC AMPERES NOMINAL 1.2 |
| CWHF | OUTPUT CONNECTION QUANTITY | 6 |
| CWHJ | OUTPUT CONNECTION TYPE | SINGLE POWER OUTPUT SCREW |
| ANPM | INPUT PHASE | SINGLE OPERATING POWER RQMT SINGLE |
| APNX | INPUT VOLTAGE RATING | SINGLE OPERATING POWER RQMT AC VOLTS MINIMUM 100.0 AND AC VOLTS MAXIMUM 240.0 |
| APPA | OUTPUT VOLTAGE RATING | SINGLE POWER OUTPUT DC VOLTS NOMINAL 12.0 |
| AGAV | END ITEM IDENTIFICATION | AID CONTROL AND MONITOR SYSTEM (1SG38-ACMS) |
| AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | ALTERNATE OPERATING |
| APTQ | INPUT FREQUENCY RATING | SINGLE OPERATING POWER RQMT HERTZ MINIMUM 47.0 AND HERTZ MAXIMUM 63.0 |
| AYNH | OPERATING AMBIENT TEMP RANGE | CELSIUS -10.0 TO 60.0 |
| CWHM | INPUT CURRENT RATING | SINGLE OPERATING POWER RQMT AC AMPERES NOMINAL 0.30 |
| ABHP | OVERALL LENGTH | INCHES NOMINAL 3.740 |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 2.950 |
| ABMK | OVERALL WIDTH | INCHES NOMINAL 1.770 |
| AMQY | INSTALLATION DESIGN | PANEL AND RACK |
Cross-references
1 manufacturer part number on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| PS5R-B12 | 60886 |