NSN 6120-01-619-1535 · NIIN 016191535 · FSC 6120
NO DASHES 6120016191535
In Stock
POWER SUPPLY
Transformers: Distribution and Power Station
Application: 721S-XA VERY HIGH FREQ/ULTRA HIGH FREQ FIXED SITE RADIO
Technical characteristics
15 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | 28V VDC POWER SUPPLY |
| APNX | INPUT VOLTAGE RATING | FIRST ALTERNATE OPERATING POWER RQMT AC VOLTS MINIMUM 85.0 AND AC VOLTS MAXIMUM 264.0 |
| APNX | INPUT VOLTAGE RATING | SECOND ALTERNATE OPERATING POWER RQMT DC VOLTS MINIMUM 120.0 AND DC VOLTS MAXIMUM 370.0 |
| APPA | OUTPUT VOLTAGE RATING | SINGLE POWER OUTPUT DC VOLTS NOMINAL 15.0 |
| ABKW | OVERALL HEIGHT | MILLIMETERS NOMINAL 43.0 |
| ABMK | OVERALL WIDTH | MILLIMETERS NOMINAL 127.0 |
| AGAV | END ITEM IDENTIFICATION | 721S-XA VERY HIGH FREQ/ULTRA HIGH FREQ FIXED SITE RADIO |
| CWGH | OUTPUT CURRENT RATING | SINGLE POWER OUTPUT DC AMPERES NOMINAL 32.0 |
| CWHM | INPUT CURRENT RATING | FIRST ALTERNATE OPERATING POWER RQMT AC AMPERES MINIMUM 3.5 AND AC AMPERES MAXIMUM 6.5 |
| CWKG | VENTILATION DESIGN TYPE | DUAL FAN |
| CWWY | POWER SUPPLY EFFICIENCY LINE | 85.0 |
| ABHP | OVERALL LENGTH | MILLIMETERS NOMINAL 296.0 |
| AYNH | OPERATING AMBIENT TEMP RANGE | CELSIUS -20.0 TO 60.0 |
| BGQR | OUTPUT WATTAGE RATING | SINGLE POWER OUTPUT WATTS NOMINAL 480.0 |
| APTQ | INPUT FREQUENCY RATING | FIRST ALTERNATE OPERATING POWER RQMT HERTZ NOMINAL 60.0 |
Cross-references
2 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| SP-480-15 | S8116 |
| 270-3148-208 | 09344 |