NSN 6120-01-680-9096 · NIIN 016809096 · FSC 6120
NO DASHES 6120016809096
In Stock
POWER SUPPLY
Transformers: Distribution and Power Station
Technical characteristics
16 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ANPM | INPUT PHASE | SINGLE OPERATING POWER RQMT SINGLE |
| BGQR | OUTPUT WATTAGE RATING | SINGLE POWER OUTPUT WATTS NOMINAL 960.0 |
| CWGH | OUTPUT CURRENT RATING | SINGLE POWER OUTPUT DC AMPERES MINIMUM 0.1 AND DC AMPERES MAXIMUM 30.0 |
| CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | SWITCHING DC POWER SUPPLY |
| CWHM | INPUT CURRENT RATING | SINGLE OPERATING POWER RQMT AC AMPERES MINIMUM 4.5 AND AC AMPERES MAXIMUM 9.0 |
| APTQ | INPUT FREQUENCY RATING | SINGLE OPERATING POWER RQMT HERTZ MINIMUM 50.0 AND HERTZ MAXIMUM 60.0 |
| APTS | OUTPUT FREQUENCY RATING | SINGLE POWER OUTPUT KILOHERTZ MINIMUM 75.0 AND KILOHERTZ MAXIMUM 85.0 |
| ABMK | OVERALL WIDTH | INCHES NOMINAL 7.9 |
| APNX | INPUT VOLTAGE RATING | SINGLE OPERATING POWER RQMT AC VOLTS MINIMUM 110.0 AND AC VOLTS MAXIMUM 230.0 |
| AMQY | INSTALLATION DESIGN | TABLE |
| ABHP | OVERALL LENGTH | INCHES NOMINAL 10.8 |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 3.5 |
| APPA | OUTPUT VOLTAGE RATING | SINGLE POWER OUTPUT DC VOLTS MINIMUM 1.0 AND DC VOLTS MAXIMUM 32.0 |
| AYNH | OPERATING AMBIENT TEMP RANGE | CELSIUS -0.1 TO 40.0 |
| CWGZ | RIPPLE VOLTAGE AT FULL LOAD | SINGLE POWER OUTPUT MILLIVOLTS RMS 5.0 AND MILLIVOLTS PEAK 50.0 |
| CWKG | VENTILATION DESIGN TYPE | SINGLE FAN |