NSN 6120-01-701-8032 · NIIN 017018032 · FSC 6120
NO DASHES 6120017018032
In Stock
TRANSFORMER,POWER
Transformers: Distribution and Power Station
Application: KC-390
Technical characteristics
27 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | ALL MOUNTING FACILITIES SINGLE CENTER GROUP MILLIMETERS NOMINAL 181.0 |
| ADAT | BODY WIDTH | MILLIMETERS NOMINAL 205.70 |
| ADAQ | BODY LENGTH | MILLIMETERS NOMINAL 263.30 |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | ALL MOUNTING FACILITIES SINGLE CENTER GROUP MILLIMETERS NOMINAL 288.3 |
| TTQY | TERMINAL TYPE AND QUANTITY | CONNECTOR, RECEPTACLE 2 AND TERMINAL BLOCK W/SCREWS 1 |
| AFHN | INSTALLATION FOR WHICH DESIGNED | INDOOR NONPORTABLE |
| AGAV | END ITEM IDENTIFICATION | KC-390 |
| BFMF | COOLING METHOD | SELF-COOLED |
| ABHP | OVERALL LENGTH | MILLIMETERS NOMINAL 307.3 |
| ACZB | FREQUENCY RATING | SINGLE COMPONENT HERTZ MINIMUM 360.0 AND HERTZ MAXIMUM 650.0 |
| ABKW | OVERALL HEIGHT | MILLIMETERS NOMINAL 255.60 |
| ABMK | OVERALL WIDTH | MILLIMETERS NOMINAL 205.70 |
| ABTB | MOUNTING HOLE DIAMETER | SINGLE GROUP MILLIMETERS MINIMUM 14.3 |
| AKPV | MOUNTING FACILITY QUANTITY | 4 |
| AXGY | MOUNTING METHOD | SINGLE GROUP TAB AND UNTHREADED HOLE(S) |
| AFHM | MOUNTING TAB WIDTH | MILLIMETERS NOMINAL 22.0 |
| FEAT | SPECIAL FEATURES | TRANSFORMER RECTIFIER UNIT CONVERTS 115/200 V AC, 360-650 HZ, 3-PHASE INPUT POWER SOURCE TO 28 VDC, 300 ADC. SIX PHASE-TWELVE PULSE, LOW RIPPLE, SYNCHRONOUS RECTIFICATION. LNPUT/OUTPUT ISOLATION IS OFFERED VIA SEPARATE PRIMARY AND SECONDARY TRANSFORMER WINDINGS. WEIGHT 13.6 KG MAX. UNIT MAY BE GROUNDED TO AIRFRAME USING MOUNTING HOLES. BONDING RESISTANCE 2.5 MILLIOHMS MAX WHEN MEASURED BETWEEN CONNECTOR SHELL AND TRU MOUNTING PLATE. D38999/20FC35PN (J2) MATES WITH D38999/26FC35SN OR EQUIVALENT AIRCRAFT SIGNAL. MS3452L22-22P (J1) MATES WITH MS3459L22-22S OR EQUIVALENT AC INPUT. 2X COOLING FAN. |
| PRPY | PROPRIETARY CHARACTERISTICS | PACS |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT THREE PHASE TO SINGLE PHASE |
| ACZD | TRANSFORMER WINDING CONNECTION TYPE | WYE-WYE |
| CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | 300 AMPERE TRANSFORMER RECTIFIER UNIT (TRU) |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT FIRST PRIMARY INPUT AC VOLTS MINIMUM 115.0 AND AC VOLTS MAXIMUM 200.0 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT FIRST PRIMARY OUTPUT DC VOLTS NOMINAL 28.0 |
| AKNA | INCLOSURE TYPE | PARTIALLY INCLOSED |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT FIRST PRIMARY INPUT AMPERES AC NOMINAL 28.0 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT FIRST PRIMARY OUTPUT AMPERES DC NOMINAL 300.0 |
| ADAU | BODY HEIGHT | MILLIMETERS NOMINAL 255.60 |
Cross-references
3 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| TRU2-300-5 | 1M2T3 |
| TRU2-300-5 REV 2 | 1M2T3 |
| RPT4252 REV 5 | 7BBU4 |