Home / MS parts / NSN 6130-01-027-9013
NSN 6130-01-027-9013  ·  NIIN 010279013  ·  FSC 6130
NO DASHES 6130010279013
In Stock

POWER SUPPLY

Converters, Electrical, Nonrotating

Technical characteristics

38 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
ABHPOVERALL LENGTHINCHES NOMINAL 9.000
ABKWOVERALL HEIGHTINCHES NOMINAL 3.200
ABMKOVERALL WIDTHINCHES NOMINAL 4.900
AKWCELECTRICAL POWER SOURCE RELATIONSHIPOPERATING
ANPMINPUT PHASESECOND OPERATING POWER RQMT SINGLE
ANPMINPUT PHASEFIRST OPERATING POWER RQMT SINGLE
APNXINPUT VOLTAGE RATINGFIRST OPERATING POWER RQMT AC VOLTS MINIMUM 210.0 AND AC VOLTS MAXIMUM 250.0
APNXINPUT VOLTAGE RATINGSECOND OPERATING POWER RQMT AC VOLTS MINIMUM 105.0 AND AC VOLTS MAXIMUM 125.0
APPAOUTPUT VOLTAGE RATINGFIRST POWER OUTPUT DC VOLTS MINIMUM 12.0 AND DC VOLTS MAXIMUM 15.0
APPAOUTPUT VOLTAGE RATINGSECOND POWER OUTPUT DC VOLTS NOMINAL 5.0
APPAOUTPUT VOLTAGE RATINGFOURTH POWER OUTPUT DC VOLTS MINIMUM -12.0 AND DC VOLTS MAXIMUM -15.0
APPAOUTPUT VOLTAGE RATINGTHIRD POWER OUTPUT DC VOLTS NOMINAL -5.0
APTQINPUT FREQUENCY RATINGFIRST OPERATING POWER RQMT HERTZ MINIMUM 47.0 AND HERTZ MAXIMUM 400.0
APTQINPUT FREQUENCY RATINGSECOND OPERATING POWER RQMT HERTZ MINIMUM 47.0 AND HERTZ MAXIMUM 400.0
AYNHOPERATING AMBIENT TEMP RANGECELSIUS 0.1 TO 70.0
BGHXOUTPUT CONTROL QUANTITY1
BGHYOUTPUT CONTROL TYPEFIRST POWER OUTPUT VOLTAGE ADJUSTMENT
BGHYOUTPUT CONTROL TYPETHIRD POWER OUTPUT VOLTAGE ADJUSTMENT
BGHYOUTPUT CONTROL TYPEFOURTH POWER OUTPUT VOLTAGE ADJUSTMENT
BGHYOUTPUT CONTROL TYPESECOND POWER OUTPUT VOLTAGE ADJUSTMENT
BHQNRECTIFICATION METHODSINGLE PHASE FULL WAVE CENTER TAP
CBBLFEATURES PROVIDEDEMI FILTER
CWGHOUTPUT CURRENT RATINGSECOND POWER OUTPUT DC AMPERES NOMINAL 6.0
CWGHOUTPUT CURRENT RATINGTHIRD POWER OUTPUT DC MILLIAMPERES NOMINAL 400.0
CWGHOUTPUT CURRENT RATINGFOURTH POWER OUTPUT DC AMPERES NOMINAL 1.0
CWGHOUTPUT CURRENT RATINGFIRST POWER OUTPUT DC AMPERES NOMINAL 1.0
CWHCOUTPUT CONTROL LOCATIONFIRST POWER OUTPUT FRONT PANEL
CWHCOUTPUT CONTROL LOCATIONSECOND POWER OUTPUT FRONT PANEL
CWHCOUTPUT CONTROL LOCATIONFOURTH POWER OUTPUT FRONT PANEL
CWHCOUTPUT CONTROL LOCATIONTHIRD POWER OUTPUT FRONT PANEL
CWHFOUTPUT CONNECTION QUANTITY5
CWHJOUTPUT CONNECTION TYPESECOND POWER OUTPUT TERMINAL STRIP
CWHJOUTPUT CONNECTION TYPETHIRD POWER OUTPUT TERMINAL STRIP
CWHJOUTPUT CONNECTION TYPEFOURTH POWER OUTPUT TERMINAL STRIP
CWHJOUTPUT CONNECTION TYPEFIRST POWER OUTPUT TERMINAL STRIP
CWHQINPUT CONNECTION TYPEFIRST OPERATING POWER RQMT TERMINAL STRIP
CWHQINPUT CONNECTION TYPESECOND OPERATING POWER RQMT TERMINAL STRIP
CWKGVENTILATION DESIGN TYPEAMBIENT AIR

Cross-references

3 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.

Manufacturer cross-reference part numbers and CAGE codes
Manufacturer part numberCAGE
ET401-108742
ET401-1108742
270-0727-04013499