NSN 6130-01-127-9610 · NIIN 011279610 · FSC 6130
NO DASHES 6130011279610
In Stock
POWER SUPPLY
Converters, Electrical, Nonrotating
Technical characteristics
20 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ABHP | OVERALL LENGTH | INCHES NOMINAL 5.625 |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 2.594 |
| ABMK | OVERALL WIDTH | INCHES NOMINAL 4.875 |
| AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
| ANPM | INPUT PHASE | SECOND OPERATING POWER RQMT SINGLE |
| ANPM | INPUT PHASE | FIRST OPERATING POWER RQMT SINGLE |
| APNX | INPUT VOLTAGE RATING | SECOND OPERATING POWER RQMT AC VOLTS MINIMUM 105.0 AND AC VOLTS MAXIMUM 127.0 |
| APNX | INPUT VOLTAGE RATING | FIRST OPERATING POWER RQMT AC VOLTS MINIMUM 210.0 AND AC VOLTS MAXIMUM 254.0 |
| APPA | OUTPUT VOLTAGE RATING | SINGLE POWER OUTPUT DC VOLTS NOMINAL 28.0 |
| APTQ | INPUT FREQUENCY RATING | FIRST OPERATING POWER RQMT HERTZ MINIMUM 47.0 AND HERTZ MAXIMUM 440.0 |
| APTQ | INPUT FREQUENCY RATING | SECOND OPERATING POWER RQMT HERTZ MINIMUM 47.0 AND HERTZ MAXIMUM 440.0 |
| AYNH | OPERATING AMBIENT TEMP RANGE | CELSIUS 0.1 TO 60.0 |
| BGHX | OUTPUT CONTROL QUANTITY | 1 |
| BGHY | OUTPUT CONTROL TYPE | SINGLE POWER OUTPUT VOLTAGE ADJUSTMENT |
| BHQN | RECTIFICATION METHOD | SINGLE PHASE FULL WAVE CENTER TAP |
| CBBL | FEATURES PROVIDED | FILTER |
| CWGH | OUTPUT CURRENT RATING | SINGLE POWER OUTPUT DC AMPERES MAXIMUM 2.0 |
| CWHF | OUTPUT CONNECTION QUANTITY | 2 |
| CWHJ | OUTPUT CONNECTION TYPE | SINGLE POWER OUTPUT TERMINAL STRIP |
| CWKG | VENTILATION DESIGN TYPE | AMBIENT AIR |
Cross-references
3 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| LOSY28 | 80103 |
| HSD-28-4.0 | 9T790 |
| LNSX28 | 9T790 |