NSN 6130-01-233-6204 · NIIN 012336204 · FSC 6130
NO DASHES 6130012336204
In Stock
POWER SUPPLY
Converters, Electrical, Nonrotating
Technical characteristics
17 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | ALTERNATE OPERATING |
| ANPM | INPUT PHASE | SINGLE OPERATING POWER RQMT SINGLE |
| ANRQ | FREQUENCY REGULATION PERCENT | 10.0 |
| ANRQ | FREQUENCY REGULATION PERCENT | 5.0 |
| ANRQ | FREQUENCY REGULATION PERCENT | 20.0 |
| APNX | INPUT VOLTAGE RATING | SINGLE OPERATING POWER RQMT AC VOLTS MINIMUM 100.0 AND AC VOLTS MAXIMUM 130.0 |
| APPA | OUTPUT VOLTAGE RATING | SECOND POWER OUTPUT DC VOLTS NOMINAL 5.0 |
| APPA | OUTPUT VOLTAGE RATING | FIRST POWER OUTPUT DC VOLTS NOMINAL 24.0 |
| APPA | OUTPUT VOLTAGE RATING | THIRD POWER OUTPUT DC VOLTS NOMINAL -5.0 |
| AYNH | OPERATING AMBIENT TEMP RANGE | CELSIUS -28.0 TO 90.0 |
| CWGW | POWER SUPPLY OUTPUT CURRENT/VOLTAGE CHARACTERISTICS | SECOND POWER OUTPUT CONSTANT VOLTAGE |
| CWGW | POWER SUPPLY OUTPUT CURRENT/VOLTAGE CHARACTERISTICS | FIRST POWER OUTPUT CONSTANT VOLTAGE |
| CWGW | POWER SUPPLY OUTPUT CURRENT/VOLTAGE CHARACTERISTICS | THIRD POWER OUTPUT CONSTANT VOLTAGE |
| CWGZ | RIPPLE VOLTAGE AT FULL LOAD | FIRST POWER OUTPUT MILLIVOLTS RMS 25.0 |
| CWGZ | RIPPLE VOLTAGE AT FULL LOAD | THIRD POWER OUTPUT MILLIVOLTS RMS 25.0 |
| CWGZ | RIPPLE VOLTAGE AT FULL LOAD | SECOND POWER OUTPUT MILLIVOLTS RMS 50.0 |
| CWHT | INPUT CONNECTION QUANTITY | 1 |