NSN 6130-01-249-2359 · NIIN 012492359 · FSC 6130
NO DASHES 6130012492359
In Stock
POWER SUPPLY
Converters, Electrical, Nonrotating
Application: AN/TRC-170 LOOP TS
Technical characteristics
21 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ABHP | OVERALL LENGTH | INCHES NOMINAL 5.000 |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 2.030 |
| ABMK | OVERALL WIDTH | INCHES NOMINAL 4.280 |
| ADZC | ENVIRONMENTAL PROTECTION | FUNGUS PROOF |
| AGAV | END ITEM IDENTIFICATION | AN/TRC-170 LOOP TS |
| AKAE | MAXIMUM OPERATING ALTITUDE RATING | FEET 10000.0 |
| AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
| ANPM | INPUT PHASE | SINGLE OPERATING POWER RQMT SINGLE |
| APNX | INPUT VOLTAGE RATING | SINGLE OPERATING POWER RQMT DC VOLTS MINIMUM 103.5 AND DC VOLTS MAXIMUM 126.5 |
| APPA | OUTPUT VOLTAGE RATING | FIRST POWER OUTPUT DC VOLTS MINIMUM 14.3 AND DC VOLTS MAXIMUM 15.7 |
| APPA | OUTPUT VOLTAGE RATING | SECOND POWER OUTPUT DC VOLTS MINIMUM -14.3 AND DC VOLTS MAXIMUM -15.7 |
| APTQ | INPUT FREQUENCY RATING | SINGLE OPERATING POWER RQMT HERTZ MINIMUM 50.0 AND HERTZ MAXIMUM 420.0 |
| AYNH | OPERATING AMBIENT TEMP RANGE | CELSIUS -32.0 TO 95.0 |
| CBBL | FEATURES PROVIDED | VOLTAGE ADJUSTMENT AND OVER VOLTAGE PROTECTOR |
| CWGH | OUTPUT CURRENT RATING | FIRST POWER OUTPUT DC AMPERES NOMINAL 1.0 |
| CWGH | OUTPUT CURRENT RATING | SECOND POWER OUTPUT DC AMPERES NOMINAL -1.0 |
| CWHF | OUTPUT CONNECTION QUANTITY | 3 |
| CWHJ | OUTPUT CONNECTION TYPE | SINGLE POWER OUTPUT THREADED STUD |
| CWHQ | INPUT CONNECTION TYPE | SINGLE OPERATING POWER RQMT THREADED STUD |
| CWHT | INPUT CONNECTION QUANTITY | 2 |
| CWKG | VENTILATION DESIGN TYPE | CONVECTION |