NSN 6130-01-303-0451 · NIIN 013030451 · FSC 6130
NO DASHES 6130013030451
In Stock
POWER SUPPLY
Converters, Electrical, Nonrotating
Application: PEACE SHIELD A
Technical characteristics
22 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ABHP | OVERALL LENGTH | INCHES NOMINAL 12.437 |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 6.530 |
| ABMK | OVERALL WIDTH | INCHES NOMINAL 7.781 |
| AGAV | END ITEM IDENTIFICATION | PEACE SHIELD A |
| AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
| ANPM | INPUT PHASE | SINGLE OPERATING POWER RQMT SINGLE |
| APNX | INPUT VOLTAGE RATING | FIRST ALTERNATE OPERATING POWER RQMT AC VOLTS NOMINAL 240.0 |
| APNX | INPUT VOLTAGE RATING | FOURTH ALTERNATE OPERATING POWER RQMT AC VOLTS NOMINAL 100.0 |
| APNX | INPUT VOLTAGE RATING | THIRD ALTERNATE OPERATING POWER RQMT AC VOLTS NOMINAL 120.0 |
| APNX | INPUT VOLTAGE RATING | SECOND ALTERNATE OPERATING POWER RQMT AC VOLTS NOMINAL 220.0 |
| APPA | OUTPUT VOLTAGE RATING | FIRST POWER OUTPUT DC VOLTS MINIMUM -100.0 AND DC VOLTS MAXIMUM 100.0 |
| APPA | OUTPUT VOLTAGE RATING | SECOND POWER OUTPUT DC VOLTS MINIMUM -10.0 AND DC VOLTS MAXIMUM 10.0 |
| APTQ | INPUT FREQUENCY RATING | SINGLE OPERATING POWER RQMT HERTZ MINIMUM 48.0 AND HERTZ MAXIMUM 63.0 |
| AYNH | OPERATING AMBIENT TEMP RANGE | CELSIUS -0.1 TO 55.0 |
| CBBL | FEATURES PROVIDED | ON/OFF SWITCH INDICATOR AND DC AMMETER AND REMOTE ERROR SENSING CAPABILITY AND FUNCTION SWITCH AND CURRENT REGULATOR CIRCUIT AND VOLTAGE ADJUSTMENT AND DC VOLTMETER AND OVER VOLTAGE PROTECTOR AND REMOTE PROGRAMMING |
| CWGH | OUTPUT CURRENT RATING | SINGLE POWER OUTPUT DC AMPERES MINIMUM 0.0 AND DC AMPERES MAXIMUM 0.5 |
| CWHC | OUTPUT CONTROL LOCATION | SINGLE POWER OUTPUT FRONT PANEL |
| CWHF | OUTPUT CONNECTION QUANTITY | 2 |
| CWHJ | OUTPUT CONNECTION TYPE | SINGLE POWER OUTPUT TERMINAL STRIP |
| CWHQ | INPUT CONNECTION TYPE | SINGLE OPERATING POWER RQMT WIRE LEAD |
| CWHT | INPUT CONNECTION QUANTITY | 1 |
| CWKG | VENTILATION DESIGN TYPE | CONVECTION |