NSN 6130-01-362-0927 · NIIN 013620927 · FSC 6130
NO DASHES 6130013620927
In Stock
POWER SUPPLY
Converters, Electrical, Nonrotating
Application: AN/ALR-56 ARWR
Technical characteristics
18 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AGAV | END ITEM IDENTIFICATION | AN/ALR-56 ARWR |
| APNX | INPUT VOLTAGE RATING | FIRST ALTERNATE OPERATING POWER RQMT DC VOLTS NOMINAL 135.0 |
| APNX | INPUT VOLTAGE RATING | SECOND ALTERNATE OPERATING POWER RQMT DC VOLTS NOMINAL 15.0 |
| APPA | OUTPUT VOLTAGE RATING | THIRD POWER OUTPUT DC VOLTS NOMINAL -6.0 |
| APPA | OUTPUT VOLTAGE RATING | SIXTH POWER OUTPUT DC VOLTS NOMINAL 6.0 |
| APPA | OUTPUT VOLTAGE RATING | EIGHTH POWER OUTPUT DC VOLTS NOMINAL 28.0 |
| APPA | OUTPUT VOLTAGE RATING | FIRST POWER OUTPUT DC VOLTS NOMINAL -100.0 |
| APPA | OUTPUT VOLTAGE RATING | NINTH POWER OUTPUT DC VOLTS NOMINAL 48.0 |
| APPA | OUTPUT VOLTAGE RATING | SEVENTH POWER OUTPUT DC VOLTS NOMINAL 15.0 |
| APPA | OUTPUT VOLTAGE RATING | FIFTH POWER OUTPUT DC VOLTS NOMINAL 5.0 |
| APPA | OUTPUT VOLTAGE RATING | SECOND POWER OUTPUT DC VOLTS NOMINAL -15.2 |
| APPA | OUTPUT VOLTAGE RATING | FOURTH POWER OUTPUT DC VOLTS NOMINAL -5.2 |
| CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
| CWHQ | INPUT CONNECTION TYPE | SECOND ALTERNATE OPERATING POWER RQMT CONNECTOR, PLUG |
| CWHQ | INPUT CONNECTION TYPE | FIRST ALTERNATE OPERATING POWER RQMT CONNECTOR, PLUG |
| CWHT | INPUT CONNECTION QUANTITY | 1 |
| CWKG | VENTILATION DESIGN TYPE | INTEGRAL BLOWER |
| FEAT | SPECIAL FEATURES | ELECTROSTATIC SENSITIVE DEVICE; CONTAINS OVERLOAD PROTECTION AND POWERSUPPLY OPERATING LIFE 20,000 HOURS |
Cross-references
4 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| 330454-102 | 81413 |
| 330454 | 81413 |
| 4-602-01 | 97953 |
| 4-602-01 | 08748 |