NSN 6130-01-363-0912 · NIIN 013630912 · FSC 6130
NO DASHES 6130013630912
In Stock
POWER SUPPLY
Converters, Electrical, Nonrotating
Application: F110 ACFT/GE100 ENG
Technical characteristics
38 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ABHP | OVERALL LENGTH | INCHES NOMINAL 19.000 |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 5.250 |
| ABMK | OVERALL WIDTH | INCHES NOMINAL 16.000 |
| AGAV | END ITEM IDENTIFICATION | F110 ACFT/GE100 ENG |
| AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
| ANPM | INPUT PHASE | SECOND ALTERNATE OPERATING POWER RQMT SINGLE |
| ANPM | INPUT PHASE | FIRST ALTERNATE OPERATING POWER RQMT SINGLE |
| APNX | INPUT VOLTAGE RATING | SECOND ALTERNATE OPERATING POWER RQMT AC VOLTS NOMINAL 230.0 |
| APNX | INPUT VOLTAGE RATING | FIRST ALTERNATE OPERATING POWER RQMT AC VOLTS NOMINAL 115.0 |
| APPA | OUTPUT VOLTAGE RATING | THIRD POWER OUTPUT AC VOLTS MINIMUM 0.0 AND AC VOLTS MAXIMUM 260.0 |
| APPA | OUTPUT VOLTAGE RATING | FIRST POWER OUTPUT AC VOLTS MINIMUM 0.0 AND AC VOLTS MAXIMUM 32.0 |
| APPA | OUTPUT VOLTAGE RATING | SECOND POWER OUTPUT AC VOLTS MINIMUM 0.0 AND AC VOLTS MAXIMUM 130.0 |
| APTQ | INPUT FREQUENCY RATING | SECOND ALTERNATE OPERATING POWER RQMT HERTZ MINIMUM 47.0 AND HERTZ MAXIMUM 63.0 |
| APTQ | INPUT FREQUENCY RATING | FIRST ALTERNATE OPERATING POWER RQMT HERTZ MINIMUM 47.0 AND HERTZ MAXIMUM 63.0 |
| APTS | OUTPUT FREQUENCY RATING | SECOND POWER OUTPUT HERTZ MINIMUM 45.0 AND KILOHERTZ MAXIMUM 5.0 |
| APTS | OUTPUT FREQUENCY RATING | FIRST POWER OUTPUT HERTZ MINIMUM 45.0 AND KILOHERTZ MAXIMUM 5.0 |
| APTS | OUTPUT FREQUENCY RATING | THIRD POWER OUTPUT HERTZ MINIMUM 45.0 AND KILOHERTZ MAXIMUM 5.0 |
| AYNH | OPERATING AMBIENT TEMP RANGE | CELSIUS 0.1 TO 50.0 |
| CBBL | FEATURES PROVIDED | PROGRAMMABLE AND OVER TEMPERATURE PROTECTION AND OVER VOLTAGE PROTECTOR |
| CWGH | OUTPUT CURRENT RATING | SECOND POWER OUTPUT AC AMPERES MINIMUM 0.0 AND AC AMPERES MAXIMUM 2.25 |
| CWGH | OUTPUT CURRENT RATING | FIRST POWER OUTPUT AC AMPERES MINIMUM 0.0 AND AC AMPERES MAXIMUM 9.2 |
| CWGH | OUTPUT CURRENT RATING | THIRD POWER OUTPUT AC AMPERES MINIMUM 0.0 AND AC AMPERES MAXIMUM 1.1 |
| CWGN | OUTPUT PHASE | FIRST POWER OUTPUT TWO |
| CWGN | OUTPUT PHASE | THIRD POWER OUTPUT TWO |
| CWGN | OUTPUT PHASE | SECOND POWER OUTPUT TWO |
| CWHC | OUTPUT CONTROL LOCATION | SECOND POWER OUTPUT REAR PANEL |
| CWHC | OUTPUT CONTROL LOCATION | THIRD POWER OUTPUT REAR PANEL |
| CWHC | OUTPUT CONTROL LOCATION | FIRST POWER OUTPUT REAR PANEL |
| CWHF | OUTPUT CONNECTION QUANTITY | 1 |
| CWHJ | OUTPUT CONNECTION TYPE | FIRST POWER OUTPUT TERMINAL STRIP |
| CWHJ | OUTPUT CONNECTION TYPE | THIRD POWER OUTPUT TERMINAL STRIP |
| CWHJ | OUTPUT CONNECTION TYPE | SECOND POWER OUTPUT TERMINAL STRIP |
| CWHM | INPUT CURRENT RATING | SECOND ALTERNATE OPERATING POWER RQMT AC AMPERES NOMINAL 1500.0 |
| CWHM | INPUT CURRENT RATING | FIRST ALTERNATE OPERATING POWER RQMT AC AMPERES NOMINAL 1500.0 |
| CWHQ | INPUT CONNECTION TYPE | FIRST ALTERNATE OPERATING POWER RQMT TERMINAL STRIP |
| CWHQ | INPUT CONNECTION TYPE | SECOND ALTERNATE OPERATING POWER RQMT TERMINAL STRIP |
| CWHT | INPUT CONNECTION QUANTITY | 1 |
| FEAT | SPECIAL FEATURES | CONSIST OF:2 EA MODEL 251B;1 EA 400SR AND 1 EA 990-302-92 CABLE PLUS ASELECTED OSCILLATOR |
Cross-references
1 manufacturer part number on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| 500-2 | 25965 |