NSN 6130-01-371-2215 · NIIN 013712215 · FSC 6130
NO DASHES 6130013712215
In Stock
POWER SUPPLY
Converters, Electrical, Nonrotating
Application: AN/FLR-9
Technical characteristics
13 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ABHP | OVERALL LENGTH | INCHES NOMINAL 7.100 |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 2.370 |
| ABMK | OVERALL WIDTH | INCHES NOMINAL 4.880 |
| AGAV | END ITEM IDENTIFICATION | AN/FLR-9 |
| AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
| APNX | INPUT VOLTAGE RATING | SECOND ALTERNATE OPERATING POWER RQMT AC VOLTS MINIMUM 180.0 AND AC VOLTS MAXIMUM 264.0 |
| APNX | INPUT VOLTAGE RATING | FIRST ALTERNATE OPERATING POWER RQMT AC VOLTS MINIMUM 90.0 AND AC VOLTS MAXIMUM 132.0 |
| APPA | OUTPUT VOLTAGE RATING | SINGLE POWER OUTPUT DC VOLTS NOMINAL 24.0 |
| APTQ | INPUT FREQUENCY RATING | SINGLE OPERATING POWER RQMT HERTZ MINIMUM 47.0 AND HERTZ MAXIMUM 440.0 |
| CBBL | FEATURES PROVIDED | OVER VOLTAGE PROTECTOR AND REMOTE ERROR SENSING CAPABILITY |
| CWGH | OUTPUT CURRENT RATING | SINGLE POWER OUTPUT DC AMPERES NOMINAL 5.0 |
| CWHM | INPUT CURRENT RATING | SECOND ALTERNATE OPERATING POWER RQMT AC AMPERES NOMINAL 40.0 |
| CWHM | INPUT CURRENT RATING | FIRST ALTERNATE OPERATING POWER RQMT AC AMPERES NOMINAL 20.0 |