NSN 6140-01-486-9283 · NIIN 014869283 · FSC 6140
NO DASHES 6140014869283
In Stock
BATTERY ASSEMBLY
Batteries, Rechargeable
Application: HOISTING UNIT,AIRCRAFT NIIN 01-447-4628
Technical characteristics
10 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ABHP | OVERALL LENGTH | INCHES NOMINAL 13.09 |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 7.53 |
| AGAV | END ITEM IDENTIFICATION | HOISTING UNIT,AIRCRAFT NIIN 01-447-4628 |
| ALCD | USAGE DESIGN | HLU-196D/E |
| AQHM | COMPONENT IDENTIFYING NUMBER | DRAWING NO. 3590AS110 |
| CRTL | CRITICALITY CODE JUSTIFICATION | AGAV |
| CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | BATTERY ASSEMBLY |
| FEAT | SPECIAL FEATURES | BATTERY CHARACTERISTICS: NUMBER OF CELLS: 120, CELL SIZE: C, NUMBER OF SUB-PACKS: 6,NUMBER OF CELLS/SUB-PACK: 20,MAXIMUM OPERATING CURRENT: 10 AMPS,RATED VOLTAGE: 144VDC,CONTINUOUS CURERNT @ RATED VOLTAGE: 7 AMPS (20 MIN),PEAK CURRENT (500 MSEC): 20 AMPS |
| SPCL | SPECIAL TEST FEATURES | OPERATING TEMPERATURE RANGE IS -29C TO 49C, STORAGE TEMPERATURE IS -40C TO 60C |
| SUPP | SUPPLEMENTARY FEATURES | THE BATTERY PACK SHALL MEET ALL PERFORMANCE REQUIREMENTS WHEN OPERATING A CONTROLLER WHOSE INPUT BUS VOLTAGE SHALL BE 144VDC. THE BATTERY PACK SHALL BE CAPABLE OF OPERATING AT RATED CURRENT WITH 122VDC-BUS VOLTAGE FOR 1 MINUTE. THE IMPEDANCE LOSSES NOT TO EXCEED 5VDC AT RATED CURRENT |
Cross-references
2 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| 3590AS110-1 | 30003 |
| 3590AS110-1 | 08484 |